Environment - simulationEnvironment: startTime=0 stopTime=10000 tolerance=1e-06 numberOfIntervals=1000 stepSize=10 Regular simulation: ./ThermofluidStream_dev_ThermofluidStream.Processes.Tests.CentrifugalPump -abortSlowSimulation -alarm=1200 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0105053s reading init.xml | | | | | | 0.000958829s reading info.xml | | | | | | 0.0214262s [ 43.5%] pre-initialization | | | | | | 0.000321343s [ 0.7%] initialization | | | | | | 7.494e-06s [ 0.0%] steps | | | | | | 0.00155187s [ 3.2%] solver (excl. callbacks) | | | | | | 0.00360323s [ 7.3%] creating output-file | | | | | | 0.000383006s [ 0.8%] event-handling | | | | | | 0.00276851s [ 5.6%] overhead | | | | | | 0.0191543s [ 38.9%] simulation | | | | | | 0.0492159s [100.0%] total | | | | | events | | | | | | 7 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 990 steps taken | | | | | | 1384 calls of functionODE | | | | | | 123 evaluations of jacobian | | | | | | 19 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00414874s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.