Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=100 stepSize=0.01 Regular simulation: ./ThermofluidStream_dev_ThermofluidStream.Idealized.Tests.Processes.Isochoric.Warnings2 -abortSlowSimulation -alarm=1200 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/Isochoric.mo:108:5-108:280:writable] | | | | The following assertion has been violated at time 0.260000 | | | | ((noEvent(abs(dT2c.Q_flow) < 2.220446049250313e-16) or noEvent(abs(dT2c.du) > 2.220446049250313e-16))) --> "The heat flow rate in Warnings2.dT2c is non zero, but the difference in specific internal energy is zero, implying that the mass flow rate m_flow := Q_flow/du is infinite. | | | | The result is regularized." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/Isochoric.mo:108:5-108:280:writable] | | | | The following assertion has been violated at time 0.260000 | | | | ((noEvent(abs(dT2c.Q_flow) < 2.220446049250313e-16) or noEvent(abs(T_out2c.du) > 2.220446049250313e-16))) --> "The heat flow rate in Warnings2.T_out2c is non zero, but the difference in specific internal energy is zero, implying that the mass flow rate m_flow := Q_flow/du is infinite. | | | | The result is regularized." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/Isochoric.mo:108:5-108:280:writable] | | | | The following assertion has been violated at time 0.260000 | | | | ((noEvent(abs(dT2c.Q_flow) < 2.220446049250313e-16) or noEvent(abs(dT2.du) > 2.220446049250313e-16))) --> "The heat flow rate in Warnings2.dT2 is non zero, but the difference in specific internal energy is zero, implying that the mass flow rate m_flow := Q_flow/du is infinite. | | | | The result is regularized." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/Isochoric.mo:108:5-108:280:writable] | | | | The following assertion has been violated at time 0.260000 | | | | ((noEvent(abs(dT2c.Q_flow) < 2.220446049250313e-16) or noEvent(abs(T_out2.du) > 2.220446049250313e-16))) --> "The heat flow rate in Warnings2.T_out2 is non zero, but the difference in specific internal energy is zero, implying that the mass flow rate m_flow := Q_flow/du is infinite. | | | | The result is regularized." LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00536329s reading init.xml | | | | | | 0.000434265s reading info.xml | | | | | | 0.00582s [ 77.2%] pre-initialization | | | | | | 0.000161743s [ 2.1%] initialization | | | | | | 8.205e-06s [ 0.1%] steps | | | | | | 3.63e-07s [ 0.0%] solver (excl. callbacks) | | | | | | 0.000481621s [ 6.4%] creating output-file | | | | | | 0.000206019s [ 2.7%] event-handling | | | | | | 8.8706e-05s [ 1.2%] overhead | | | | | | 0.00077247s [ 10.2%] simulation | | | | | | 0.00753912s [100.0%] total | | | | | events | | | | | | 8 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 452 steps taken | | | | | | 452 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.