Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=100 stepSize=0.01 Regular simulation: ./ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.TUMExercisesThermodynamicCycles.Exercise5TurboChargedDieselEngine.Flow -abortSlowSimulation -alarm=1200 -emit_protected -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Examples/TUMExercisesThermodynamicCycles/Exercise5TurboChargedDieselEngine/BaseModel.mo:16:3-16:87:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((T5 >= 273.15 and T5 <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= T5 <= 373.15, has value: 1700" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/Isobaric.mo:19:3-22:146:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((combustion.T_out_fixed >= 273.15 and combustion.T_out_fixed <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= combustion.T_out_fixed <= 373.15, has value: 1700" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Media/myMedia/Interfaces.mo:2463:7-2463:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((engineCompression.outlet.state.T >= 273.15 and engineCompression.outlet.state.T <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= engineCompression.outlet.state.T <= 373.15, has value: 997.23" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/PolytropicPerfectGas.mo:97:3-98:21:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((engineCompression.T_out >= 273.15 and engineCompression.T_out <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= engineCompression.T_out <= 373.15, has value: 997.23" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Media/myMedia/Interfaces.mo:2463:7-2463:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((combustion.outlet.state.T >= 273.15 and combustion.outlet.state.T <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= combustion.outlet.state.T <= 373.15, has value: 1700" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/Isobaric.mo:62:3-63:21:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((combustion.T_in >= 273.15 and combustion.T_in <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= combustion.T_in <= 373.15, has value: 997.23" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Media/myMedia/Interfaces.mo:2463:7-2463:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((engineExpansion.outlet.state.T >= 273.15 and engineExpansion.outlet.state.T <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= engineExpansion.outlet.state.T <= 373.15, has value: 632.903" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/PolytropicPerfectGas.mo:84:3-84:80:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((engineExpansion.T_in >= 273.15 and engineExpansion.T_in <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= engineExpansion.T_in <= 373.15, has value: 1700" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/PolytropicPerfectGas.mo:97:3-98:21:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((engineExpansion.T_out >= 273.15 and engineExpansion.T_out <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= engineExpansion.T_out <= 373.15, has value: 632.903" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Media/myMedia/Interfaces.mo:2463:7-2463:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((turbine.outlet.state.T >= 273.15 and turbine.outlet.state.T <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= turbine.outlet.state.T <= 373.15, has value: 616.874" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Media/myMedia/Interfaces.mo:2463:7-2463:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((turbine.adiabaticModel.state_in.T >= 273.15 and turbine.adiabaticModel.state_in.T <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= turbine.adiabaticModel.state_in.T <= 373.15, has value: 632.903" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/AdiabaticThermodynamicModels/BaseClasses/PartialIdealGas.mo:25:3-26:21:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((turbine.adiabaticModel.T_in >= 273.15 and turbine.adiabaticModel.T_in <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= turbine.adiabaticModel.T_in <= 373.15, has value: 632.903" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/AdiabaticThermodynamicModels/BaseClasses/PartialIdealGas.mo:27:3-27:62:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((turbine.adiabaticModel.T_out_is >= 273.15 and turbine.adiabaticModel.T_out_is <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= turbine.adiabaticModel.T_out_is <= 373.15, has value: 616.874" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Media/myMedia/Interfaces.mo:2463:7-2463:44:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((turbine.adiabaticModel.state_out.T >= 273.15 and turbine.adiabaticModel.state_out.T <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= turbine.adiabaticModel.state_out.T <= 373.15, has value: 616.874" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Idealized/Processes/AdiabaticThermodynamicModels/PerfectGas.mo:20:3-20:48:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((turbine.adiabaticModel.T_out >= 273.15 and turbine.adiabaticModel.T_out <= 373.15)) --> "Variable violating min/max constraint: 273.15 <= turbine.adiabaticModel.T_out <= 373.15, has value: 616.874" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00962511s reading init.xml | | | | | | 0.000733646s reading info.xml | | | | | | 0.0181034s [ 92.5%] pre-initialization | | | | | | 0.000431429s [ 2.2%] initialization | | | | | | 3.757e-06s [ 0.0%] steps | | | | | | 2.25e-07s [ 0.0%] solver (excl. callbacks) | | | | | | 0.000672642s [ 3.4%] creating output-file | | | | | | 1.002e-06s [ 0.0%] event-handling | | | | | | 0.000179417s [ 0.9%] overhead | | | | | | 0.000169228s [ 0.9%] simulation | | | | | | 0.0195611s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 100 steps taken | | | | | | 100 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.