Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=100 stepSize=0.01 Regular simulation: ./ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.ClausiusRankine.Step6MassFlowRateStep -abortSlowSimulation -alarm=1200 -emit_protected -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((massFlowRateSource.p_min >= 611.657 and massFlowRateSource.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= massFlowRateSource.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((superheater.p_min >= 611.657 and superheater.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= superheater.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((preheater.p_min >= 611.657 and preheater.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= preheater.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boiler.p_min >= 611.657 and boiler.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= boiler.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((turbine.p_min >= 611.657 and turbine.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= turbine.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pump.p_min >= 611.657 and pump.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= pump.p_min <= 1e8, has value: 100" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00791197s reading init.xml | | | | | | 0.000443352s reading info.xml | | | | | | 0.00838047s [ 32.3%] pre-initialization | | | | | | 0.00072002s [ 2.8%] initialization | | | | | | 0.000130195s [ 0.5%] steps | | | | | | 1.285e-06s [ 0.0%] solver (excl. callbacks) | | | | | | 0.000715325s [ 2.8%] creating output-file | | | | | | 0.000536374s [ 2.1%] event-handling | | | | | | 0.000464121s [ 1.8%] overhead | | | | | | 0.0150315s [ 57.9%] simulation | | | | | | 0.0259793s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 155 steps taken | | | | | | 155 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.