Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=1000 stepSize=0.001 Regular simulation: ./ThermofluidStream_ThermofluidStream.Processes.Tests.ConductionElement -abortSlowSimulation -alarm=1200 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.1.0-main/Processes/Internal/PartialConductionElement.mo:55:3-55:114:writable] | | | | The following assertion has been violated at time 0.000500 | | | | ((noEvent(conductionElement3.inlet.m_flow > conductionElement3.m_flow_assert))) --> "Negative mass flow rate at inlet" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00733253s reading init.xml | | | | | | 0.000681478s reading info.xml | | | | | | 0.000493736s [ 1.9%] pre-initialization | | | | | | 0.000222166s [ 0.8%] initialization | | | | | | 6.482e-06s [ 0.0%] steps | | | | | | 0.00090818s [ 3.4%] solver (excl. callbacks) | | | | | | 0.000889544s [ 3.4%] creating output-file | | | | | | 0.000242697s [ 0.9%] event-handling | | | | | | 0.00313787s [ 11.9%] overhead | | | | | | 0.0204863s [ 77.6%] simulation | | | | | | 0.026387s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 283 steps taken | | | | | | 398 calls of functionODE | | | | | | 85 evaluations of jacobian | | | | | | 13 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00202572s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.