Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoPower_ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001315/0.001315, allocations: 113 kB / 19.04 MB, free: 3.254 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001371/0.001371, allocations: 197.9 kB / 22.22 MB, free: 72 kB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.36/1.36, allocations: 207.6 MB / 232.8 MB, free: 11 MB / 190.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/package.mo): time 0.2911/0.2911, allocations: 49.51 MB / 334.4 MB, free: 4.676 MB / 270.1 MB " [Timeout remaining time 179] Using package ThermoPower with version 3.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE,tolerance=1e-06,outputFormat="empty",numberOfIntervals=50000,variableFilter="",fileNamePrefix="ThermoPower_ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE") translateModel(ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE,tolerance=1e-06,outputFormat="empty",numberOfIntervals=50000,variableFilter="",fileNamePrefix="ThermoPower_ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE") [Timeout 660] "Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002184/0.002184, allocations: 67.89 kB / 474.2 MB, free: 13.46 MB / 350.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1067/0.1089, allocations: 62.33 MB / 0.5239 GB, free: 14.93 MB / 414.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/PowerPlants.mo:18204:30-18204:37:writable] Error: Modified element Pn not found in class Grid. Notification: Performance of FrontEnd: time 0.2372/0.3461, allocations: 35.82 MB / 0.5589 GB, free: 3.77 MB / 414.1 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 2.8192933099344373]