Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr SiemensPower_SiemensPower.Components.Junctions.Tests.splitterMixer_testTubeOwnMedia.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/package.mo", uses=false) Using package SiemensPower with version 2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(SiemensPower.Components.Junctions.Tests.splitterMixer_testTubeOwnMedia,tolerance=1e-06,outputFormat="empty",numberOfIntervals=1000,variableFilter="",fileNamePrefix="SiemensPower_SiemensPower.Components.Junctions.Tests.splitterMixer_testTubeOwnMedia") translateModel(SiemensPower.Components.Junctions.Tests.splitterMixer_testTubeOwnMedia,tolerance=1e-06,outputFormat="empty",numberOfIntervals=1000,variableFilter="",fileNamePrefix="SiemensPower_SiemensPower.Components.Junctions.Tests.splitterMixer_testTubeOwnMedia") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.007685/0.007685, allocations: 104.6 kB / 15.74 MB, free: 6.484 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001427/0.001428, allocations: 189.1 kB / 16.67 MB, free: 6.379 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.68/1.68, allocations: 205.1 MB / 222.5 MB, free: 4.508 MB / 174.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/package.mo): time 0.02962/0.02962, allocations: 5.57 MB / 275.5 MB, free: 15.59 MB / 238.1 MB Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: SiemensPower requested package Modelica of version 3.2.1. Modelica 3.2.3 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.001323/0.001323, allocations: 71.89 kB / 383.3 MB, free: 11.86 MB / 286.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.26/0.2614, allocations: 47.87 MB / 431.2 MB, free: 9.277 MB / 318.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/Components/Junctions/Tests/splitterMixer_testTubeOwnMedia.mo:21:5-21:19:writable] Error: Modified element use_h_in not found in class WaterSourceMH. Notification: Performance of FrontEnd: time 0.002393/0.2638, allocations: 1.629 MB / 432.8 MB, free: 8.133 MB / 318.1 MB