Environment - simulationEnvironment: startTime=0 stopTime=20 tolerance=1e-08 numberOfIntervals=2500 stepSize=0.008 Regular simulation: ./ScalableTestSuite_ScalableTestSuite.Thermal.HeatExchanger.ScaledExperiments.CounterCurrentHeatExchangerEquations_N_1280 -s=ida -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 4.0566e-05s [ 0.0%] pre-initialization | | | | | | 0.00135991s [ 0.3%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.21515s [ 43.0%] solver (excl. callbacks) | | | | | | 0.00865005s [ 1.7%] creating output-file | | | | | | 0.000703324s [ 0.1%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.274324s [ 54.8%] simulation | | | | | | 0.500227s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 2 time events | | | | | solver: ida | | | | | | 2519 steps taken | | | | | | 3062 calls of functionODE | | | | | | 79 evaluations of jacobian | | | | | | 4 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0148126s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.