Environment - simulationEnvironment: startTime=0 stopTime=0.1 tolerance=1e-06 numberOfIntervals=10000 stepSize=1e-05 Regular simulation: ./Modelica_4.0.0_Modelica.Electrical.PowerConverters.Examples.DCDC.ChopperStepDown.ChopperStepDown_R -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00238978s reading init.xml | | | | | | 0.000233949s reading info.xml | | | | | | 0.000240481s [ 0.3%] pre-initialization | | | | | | 0.000221215s [ 0.3%] initialization | | | | | | 0.000110948s [ 0.1%] steps | | | | | | 0.00629806s [ 8.5%] solver (excl. callbacks) | | | | | | 0.00252793s [ 3.4%] creating output-file | | | | | | 0.0288638s [ 38.9%] event-handling | | | | | | 0.00149022s [ 2.0%] overhead | | | | | | 0.0344338s [ 46.4%] simulation | | | | | | 0.0741864s [100.0%] total | | | | | events | | | | | | 176 state events | | | | | | 101 time events | | | | | solver: dassl | | | | | | 6671 steps taken | | | | | | 8406 calls of functionODE | | | | | | 2636 evaluations of jacobian | | | | | | 186 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00563829s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.