Environment - simulationEnvironment: startTime=0 stopTime=0.2 tolerance=1e-06 numberOfIntervals=2000 stepSize=0.0001 Regular simulation: ./Modelica_3.2.3_Modelica.Magnetic.FluxTubes.Examples.Hysteresis.ThreePhaseTransformerWithRectifier -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00950428s reading init.xml | | | | | | 0.000770074s reading info.xml | | | | | | 0.000229771s [ 0.0%] pre-initialization | | | | | | 0.000257012s [ 0.0%] initialization | | | | | | 0.0015524s [ 0.1%] steps | | | | | | 0.0939123s [ 5.6%] solver (excl. callbacks) | | | | | | 0.00216544s [ 0.1%] creating output-file | | | | | | 0.52919s [ 31.4%] event-handling | | | | | | 0.00487978s [ 0.3%] overhead | | | | | | 1.05236s [ 62.5%] simulation | | | | | | 1.68455s [100.0%] total | | | | | events | | | | | | 353 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 48389 steps taken | | | | | | 63856 calls of functionODE | | | | | | 5603 evaluations of jacobian | | | | | | 532 error test failures | | | | | | 322 convergence test failures | | | | | | 0.4789s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.