Environment - simulationEnvironment: startTime=0 stopTime=2 tolerance=1e-06 numberOfIntervals=2000 stepSize=0.001 Regular simulation: ./Modelica_3.2.1_Modelica.Thermal.FluidHeatFlow.Examples.WaterPump -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00354669s reading init.xml | | | | | | 0.000392005s reading info.xml | | | | | | 8.5089e-05s [ 0.5%] pre-initialization | | | | | | 0.000193522s [ 1.2%] initialization | | | | | | 3.076e-06s [ 0.0%] steps | | | | | | 0.000800078s [ 4.8%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00502652s [ 30.1%] event-handling | | | | | | 0.00081708s [ 4.9%] overhead | | | | | | 0.00975339s [ 58.5%] simulation | | | | | | 0.0166788s [100.0%] total | | | | | events | | | | | | 11 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 184 steps taken | | | | | | 184 calls of functionODE | | | | | | 175 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 3.4364e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.