Environment - simulationEnvironment: startTime=0 stopTime=2.05 tolerance=1e-06 numberOfIntervals=20500 stepSize=0.0001 Regular simulation (default: the solver the model asks for, DASSL unless it says otherwise): ./ModelicaTest_trunk_ModelicaTest.Electrical.Machines.Examples.SynchronousMachines.SMEE_DOL -abortSlowSimulation -alarm=240 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0234288s reading init.xml | | | | | | 0.000769677s reading info.xml | | | | | | 0.000108494s [ 0.1%] pre-initialization | | | | | | 0.000209554s [ 0.2%] initialization | | | | | | 3.076e-06s [ 0.0%] steps | | | | | | 0.00483305s [ 4.9%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00221822s [ 2.2%] event-handling | | | | | | 0.00725641s [ 7.3%] overhead | | | | | | 0.0844384s [ 85.2%] simulation | | | | | | 0.0990672s [100.0%] total | | | | | events | | | | | | 3 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 1741 steps taken | | | | | | 2116 calls of functionODE | | | | | | 113 evaluations of jacobian | | | | | | 36 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00140297s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.