Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr IndustrialControlSystems_IndustrialControlSystems.Applications.ProcessControl.VelocityDriveControl_AutoTuning.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/IndustrialControlSystems 1.1.0-master/package.mo", uses=false) Using package IndustrialControlSystems with version 1.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/IndustrialControlSystems 1.1.0-master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(IndustrialControlSystems.Applications.ProcessControl.VelocityDriveControl_AutoTuning,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IndustrialControlSystems_IndustrialControlSystems.Applications.ProcessControl.VelocityDriveControl_AutoTuning") translateModel(IndustrialControlSystems.Applications.ProcessControl.VelocityDriveControl_AutoTuning,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IndustrialControlSystems_IndustrialControlSystems.Applications.ProcessControl.VelocityDriveControl_AutoTuning") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.007631/0.007631, allocations: 106.1 kB / 15.73 MB, free: 6.047 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001396/0.001396, allocations: 196.6 kB / 16.67 MB, free: 5.961 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.698/1.698, allocations: 205.1 MB / 222.5 MB, free: 4.516 MB / 174.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/IndustrialControlSystems 1.1.0-master/package.mo): time 0.05653/0.05653, allocations: 10.74 MB / 280.6 MB, free: 10.41 MB / 238.1 MB Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.001685/0.001685, allocations: 63.89 kB / 390.8 MB, free: 5.031 MB / 286.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3996/0.4013, allocations: 49.01 MB / 439.8 MB, free: 5.355 MB / 318.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Electrical/Machines.mo:15250:7-15252:70:writable] Warning: Parameter M1.TaOperational has no value, and is fixed during initialization (fixed=true), using available start value (start=293.15) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Electrical/Machines.mo:15261:7-15263:54:writable] Warning: Parameter M1.TaNominal has no value, and is fixed during initialization (fixed=true), using available start value (start=293.15) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Electrical/Machines.mo:15264:7-15266:71:writable] Warning: Parameter M1.Ra has no value, and is fixed during initialization (fixed=true), using available start value (start=0.05) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Electrical/Machines.mo:15267:7-15269:71:writable] Warning: Parameter M1.TaRef has no value, and is fixed during initialization (fixed=true), using available start value (start=293.15) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Electrical/Machines.mo:15270:7-15272:71:writable] Warning: Parameter M1.alpha20a has no value, and is fixed during initialization (fixed=true), using available start value (start=0) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Electrical/Machines.mo:15273:7-15275:71:writable] Warning: Parameter M1.La has no value, and is fixed during initialization (fixed=true), using available start value (start=0.0015) as default value. Notification: Performance of NFInst.instantiate(IndustrialControlSystems.Applications.ProcessControl.VelocityDriveControl_AutoTuning): time 0.01123/0.4126, allocations: 7.908 MB / 447.7 MB, free: 15.71 MB / 334.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IndustrialControlSystems 1.1.0-master/Controllers/AutoTuning/ATPIrelayNCmixedMode.mo:91:8-91:29:writable] Error: Operator reinit may not be used in an algorithm section (use translation flag --allowNonStandardModelica=reinitInAlgorithms to ignore). Notification: Performance of FrontEnd: time 0.0006597/0.4132, allocations: 173.5 kB / 447.9 MB, free: 15.59 MB / 334.1 MB