Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0004 Regular simulation: ./Buildings_latest_Buildings.Fluid.Movers.Validation.PumpCurveDerivatives -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((forcedPump1.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in PumpCurveDerivatives.forcedPump1: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (forcedPump1.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or forcedPump1.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in PumpCurveDerivatives.forcedPump1: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((forcedPump1.per.haveWMot_nominal or not (forcedPump1.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or forcedPump1.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in PumpCurveDerivatives.forcedPump1: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:98:3-98:83:writable] | | | | The following assertion has been violated at time 0.423800 | | | | ((pump1.eta >= 0.0)) --> "Variable violating min constraint: 0.0 <= pump1.eta, has value: -8.54211e-05" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 0.423800 | | | | ((pump1.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pump1.heaDis.etaHyd, has value: -555.282" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 0.423800 | | | | ((pump1.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= pump1.eff.yMot, has value: -6.77122e-06" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0196359s reading init.xml | | | | | | 0.00172254s reading info.xml | | | | | | 0.000624962s [ 1.8%] pre-initialization | | | | | | 0.000687189s [ 2.0%] initialization | | | | | | 3.717e-06s [ 0.0%] steps | | | | | | 0.00115032s [ 3.3%] solver (excl. callbacks) | | | | | | 0.00186993s [ 5.4%] creating output-file | | | | | | 0.000332125s [ 1.0%] event-handling | | | | | | 0.00762545s [ 22.0%] overhead | | | | | | 0.0223712s [ 64.5%] simulation | | | | | | 0.0346649s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 256 steps taken | | | | | | 389 calls of functionODE | | | | | | 53 evaluations of jacobian | | | | | | 26 error test failures | | | | | | 0 convergence test failures | | | | | | 7.4736e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.