Environment - simulationEnvironment: startTime=0 stopTime=600 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.24 Regular simulation: ./Buildings_latest_Buildings.Fluid.Movers.Preconfigured.Validation.ControlledFlowMachinePreconfigured -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fan1.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan1.etaHyd, has value: -2.3234e-26" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fan1.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan1.heaDis.etaHyd, has value: -4.33701e-22" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fan3.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan3.eff.yMot, has value: -1.09424e-25" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 112.800000 | | | | ((fan3.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan3.etaHyd, has value: -1.55435e-06" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 112.800000 | | | | ((fan3.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan3.heaDis.etaHyd, has value: -0.000943657" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0206709s reading init.xml | | | | | | 0.00198413s reading info.xml | | | | | | 0.000725992s [ 0.7%] pre-initialization | | | | | | 0.000595026s [ 0.6%] initialization | | | | | | 3.0989e-05s [ 0.0%] steps | | | | | | 0.00462306s [ 4.5%] solver (excl. callbacks) | | | | | | 0.00235266s [ 2.3%] creating output-file | | | | | | 0.000828632s [ 0.8%] event-handling | | | | | | 0.00722876s [ 7.0%] overhead | | | | | | 0.0863531s [ 84.1%] simulation | | | | | | 0.102738s [100.0%] total | | | | | events | | | | | | 10 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 2410 steps taken | | | | | | 4038 calls of functionODE | | | | | | 251 evaluations of jacobian | | | | | | 49 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00472512s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.