Environment - simulationEnvironment: startTime=0 stopTime=100 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.04 Regular simulation: ./Buildings_9_Buildings.Fluid.FixedResistances.Validation.FlowJunctionSteadyState -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00494068s reading init.xml | | | | | | 0.000419948s reading info.xml | | | | | | 0.000392015s [ 2.6%] pre-initialization | | | | | | 0.000361919s [ 2.4%] initialization | | | | | | 1.613e-06s [ 0.0%] steps | | | | | | 0.000972975s [ 6.4%] solver (excl. callbacks) | | | | | | 0.00117474s [ 7.8%] creating output-file | | | | | | 0.000357261s [ 2.4%] event-handling | | | | | | 0.00207501s [ 13.7%] overhead | | | | | | 0.00977416s [ 64.7%] simulation | | | | | | 0.0151097s [100.0%] total | | | | | events | | | | | | 4 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 248 steps taken | | | | | | 348 calls of functionODE | | | | | | 127 evaluations of jacobian | | | | | | 24 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000118208s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.