Environment - simulationEnvironment: startTime=0 stopTime=14400 tolerance=1e-06 numberOfIntervals=2500 stepSize=5.76 Regular simulation: ./Buildings_9_Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumLoa.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumBoi.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/Fluid/Actuators/BaseClasses/ActuatorSignal.mo:22:3-29:26:writable] | | | | The following assertion has been violated at time 8634.240000 | | | | ((val.res3.y >= 0.0 and val.res3.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= val.res3.y <= 1.0, has value: 1" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Blocks/Interfaces.mo:329:5-330:56:writable] | | | | The following assertion has been violated at time 8634.240000 | | | | ((val.filter.y >= 0.0 and val.filter.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= val.filter.y <= 1.0, has value: -3.03635e-08" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0263727s reading init.xml | | | | | | 0.00219053s reading info.xml | | | | | | 0.00133128s [ 1.3%] pre-initialization | | | | | | 0.000678192s [ 0.6%] initialization | | | | | | 1.0279e-05s [ 0.0%] steps | | | | | | 0.00316941s [ 3.0%] solver (excl. callbacks) | | | | | | 0.00297306s [ 2.8%] creating output-file | | | | | | 0.0341429s [ 32.1%] event-handling | | | | | | 0.0140065s [ 13.2%] overhead | | | | | | 0.0501242s [ 47.1%] simulation | | | | | | 0.106436s [100.0%] total | | | | | events | | | | | | 29 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 1338 steps taken | | | | | | 1739 calls of functionODE | | | | | | 475 evaluations of jacobian | | | | | | 36 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0134s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.