Environment - simulationEnvironment: startTime=0 stopTime=360000 tolerance=1e-06 numberOfIntervals=2500 stepSize=144 Regular simulation: ./Buildings_9_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerBorefield -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/daf1e760b4b8bfc2ca0f78dd58b6acf6cf91586cTStep.mat" LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/daf1e760b4b8bfc2ca0f78dd58b6acf6cf91586cTStep.mat" LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/daf1e760b4b8bfc2ca0f78dd58b6acf6cf91586cTStep.mat" LOG_STDOUT | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/daf1e760b4b8bfc2ca0f78dd58b6acf6cf91586cTStep.mat" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/Fluid/Interfaces/PartialFourPortInterface.mo:28:3-29:84:writable] | | | | The following assertion has been violated at time 3840.000000 | | | | ((ets.hex.m2_flow >= 0.0 and ets.hex.m2_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= ets.hex.m2_flow <= 1e5, has value: -7.37257e-16" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/Experimental/DHC/Networks/BaseClasses/PartialDistribution2Pipe.mo:81:3-85:55:writable] | | | | The following assertion has been violated at time 28312.738701 | | | | ((ets.colHeaWat.mCon_flow[2] >= 0.0 and ets.colHeaWat.mCon_flow[2] <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= ets.colHeaWat.mCon_flow[2] <= 1e5, has value: -2.92005e-20" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/Experimental/DHC/Networks/BaseClasses/PartialDistribution2Pipe.mo:81:3-85:55:writable] | | | | The following assertion has been violated at time 28320.000000 | | | | ((ets.colChiWat.mCon_flow[2] >= 0.0 and ets.colChiWat.mCon_flow[2] <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= ets.colChiWat.mCon_flow[2] <= 1e5, has value: -2.48826e-144" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.308429s reading init.xml | | | | | | 0.0490789s reading info.xml | | | | | | 0.00979353s [ 0.0%] pre-initialization | | | | | | 16.0769s [ 31.4%] initialization | | | | | | 0.00423031s [ 0.0%] steps | | | | | | 2.88607s [ 5.6%] solver (excl. callbacks) | | | | | | 0.165492s [ 0.3%] creating output-file | | | | | | 2.70371s [ 5.3%] event-handling | | | | | | 0.21981s [ 0.4%] overhead | | | | | | 29.1768s [ 56.9%] simulation | | | | | | 51.2428s [100.0%] total | | | | | events | | | | | | 267 state events | | | | | | 6001 time events | | | | | solver: dassl | | | | | | 93146 steps taken | | | | | | 116842 calls of functionODE | | | | | | 67628 evaluations of jacobian | | | | | | 1060 error test failures | | | | | | 5 convergence test failures | | | | | | 26.914s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.