Environment - simulationEnvironment: startTime=864000 stopTime=950400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_8_Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneEnvironmentOutputVariable -abortSlowSimulation -alarm=480 -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 9.5.0-e579c2aa82 (No OpenGL), YMD=2024.03.13 00:13 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD LOG_STDOUT | info | 864000.000 OneEnvironmentOutputVariable.building: Warning from EnergyPlus: Calculated Relative Humidity out of range (PsyRhFnTdbWPb) LOG_STDOUT | info | 864000.000 OneEnvironmentOutputVariable.building: Warning from EnergyPlus: Routine=Unknown, Environment=SPAWN-RUNPERIOD, at Simulation time=01/01 00:40 - 00:40 LOG_STDOUT | info | 864000.000 OneEnvironmentOutputVariable.building: Warning from EnergyPlus: Dry-Bulb= -7.60 Humidity Ratio= 2.083E-003 Calculated Relative Humidity [%]= 103.41 LOG_STDOUT | info | 864000.000 OneEnvironmentOutputVariable.building: Warning from EnergyPlus: Relative Humidity being reset to 100.0% LOG_STDOUT | info | Output OneEnvironmentOutputVariable.TEnePlu.y has in Modelica the unit K. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0033513s reading init.xml | | | | | | 0.000310823s reading info.xml | | | | | | 4.3692e-05s [ 0.0%] pre-initialization | | | | | | 1.06595s [ 96.5%] initialization | | | | | | 1.243e-06s [ 0.0%] steps | | | | | | 2.8488e-05s [ 0.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0280662s [ 2.5%] event-handling | | | | | | 0.00342199s [ 0.3%] overhead | | | | | | 0.00723195s [ 0.7%] simulation | | | | | | 1.10474s [100.0%] total | | | | | events | | | | | | 143 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 372871 steps taken | | | | | | 372871 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 0.52sec EnergyPlus Completed Successfully. LOG_STDOUT | info | 949800.000 OneEnvironmentOutputVariable.building: Warning from EnergyPlus: ** Warning ** Calculated Relative Humidity out of range (PsyRhFnTdbWPb) LOG_STDOUT | info | 949800.000 OneEnvironmentOutputVariable.building: Warning from EnergyPlus: