Environment - simulationEnvironment: startTime=0 stopTime=14400 tolerance=1e-05 numberOfIntervals=2500 stepSize=5.76 Regular simulation: ./Buildings_3.0.0_Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:265:3-274:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumLoa.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:265:3-274:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumBoi.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/Fluid/Actuators/BaseClasses/ActuatorSignal.mo:17:3-24:26:writable] | | | | The following assertion has been violated at time 1008.000000 | | | | ((val.res3.y >= 0.0 and val.res3.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= val.res3.y <= 1.0, has value: -2.22045e-16" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Blocks/Interfaces.mo:329:5-330:56:writable] | | | | The following assertion has been violated at time 1008.000000 | | | | ((val.filter.y >= 0.0 and val.filter.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= val.filter.y <= 1.0, has value: 1" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0206438s reading init.xml | | | | | | 0.00191316s reading info.xml | | | | | | 0.000146295s [ 0.1%] pre-initialization | | | | | | 0.000676569s [ 0.7%] initialization | | | | | | 1.1101e-05s [ 0.0%] steps | | | | | | 0.00292377s [ 3.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.031502s [ 32.2%] event-handling | | | | | | 0.0136318s [ 13.9%] overhead | | | | | | 0.0489122s [ 50.0%] simulation | | | | | | 0.0978037s [100.0%] total | | | | | events | | | | | | 29 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 1022 steps taken | | | | | | 1330 calls of functionODE | | | | | | 472 evaluations of jacobian | | | | | | 26 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0128357s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.