Environment - simulationEnvironment: startTime=2.592e+06 stopTime=3.6288e+06 tolerance=1e-06 numberOfIntervals=2500 stepSize=414.72 Regular simulation: ./Buildings_13_Buildings.DHC.Loads.Cooling.Examples.BuildingTimeSeriesWithETS -abortSlowSimulation -alarm=240 -lv LOG_STATS LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Resources/Data/DHC/Loads/Examples/MediumOffice-90.1-2010-5A.mos" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/BaseClasses/WetCoilUARated.mo:137:3-143:34:writable] | | | | The following assertion has been violated during initialization at time 2592000.000000 | | | | ((buiWitETS.bui.terUniCoo.hexWetNtu.UAFroRated.isFulDry or buiWitETS.bui.terUniCoo.hexWetNtu.UAFroRated.isFulWet)) --> "In BuildingTimeSeriesWithETS.buiWitETS.bui.terUniCoo.hexWetNtu.UAFroRated: The nominal conditions correspond to a partially-wet coil regime. The modeling uncertainty under such conditions has not been assessed. Rather specify nominal conditions in fully-dry or fully-wet regime." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68:3-73:35:writable] | | | | The following assertion has been violated at time 2593244.160000 | | | | ((buiWitETS.bui.terUniCoo.hexWetNtu.SHR >= 0.0 and buiWitETS.bui.terUniCoo.hexWetNtu.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= buiWitETS.bui.terUniCoo.hexWetNtu.SHR <= 1.0, has value: -2.29779e-45" LOG_ASSERT | debug | Buildings_13_Buildings.DHC.Loads.Cooling.Examples.BuildingTimeSeriesWithETS_functions.c:3777: Invalid root: (-0.0756108)^(-1.5) LOG_ASSERT | debug | Buildings_13_Buildings.DHC.Loads.Cooling.Examples.BuildingTimeSeriesWithETS_functions.c:3787: Invalid root: (-0.0756108)^(-1.5) LOG_ASSERT | debug | Buildings_13_Buildings.DHC.Loads.Cooling.Examples.BuildingTimeSeriesWithETS_functions.c:3826: Invalid root: (-0.0756108)^(-1.25) LOG_ASSERT | debug | Buildings_13_Buildings.DHC.Loads.Cooling.Examples.BuildingTimeSeriesWithETS_functions.c:3836: Invalid root: (-0.0756108)^(-1.25) LOG_ASSERT | debug | Buildings_13_Buildings.DHC.Loads.Cooling.Examples.BuildingTimeSeriesWithETS_functions.c:3777: Invalid root: (-4.00983)^(-1.5) LOG_ASSERT | debug | Buildings_13_Buildings.DHC.Loads.Cooling.Examples.BuildingTimeSeriesWithETS_functions.c:3787: Invalid root: (-4.00983)^(-1.5) LOG_ASSERT | debug | Buildings_13_Buildings.DHC.Loads.Cooling.Examples.BuildingTimeSeriesWithETS_functions.c:3826: Invalid root: (-4.00983)^(-1.25) LOG_ASSERT | debug | Buildings_13_Buildings.DHC.Loads.Cooling.Examples.BuildingTimeSeriesWithETS_functions.c:3836: Invalid root: (-4.00983)^(-1.25) LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0283508s reading init.xml | | | | | | 0.00276142s reading info.xml | | | | | | 0.000172224s [ 0.1%] pre-initialization | | | | | | 0.00220421s [ 1.6%] initialization | | | | | | 1.3295e-05s [ 0.0%] steps | | | | | | 0.0076243s [ 5.4%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00171824s [ 1.2%] event-handling | | | | | | 0.00306454s [ 2.2%] overhead | | | | | | 0.127213s [ 89.6%] simulation | | | | | | 0.14201s [100.0%] total | | | | | events | | | | | | 24 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 6514 steps taken | | | | | | 10869 calls of functionODE | | | | | | 1859 evaluations of jacobian | | | | | | 655 error test failures | | | | | | 194 convergence test failures | | | | | | 0.0352719s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.