Environment - simulationEnvironment:
startTime=1.57248e+07
stopTime=1.63296e+07
tolerance=1e-06
numberOfIntervals=2500
stepSize=241.92
Regular simulation: ./Buildings_12_Buildings.DHC.Examples.Cooling.ElectricChillersDirectETS  -abortSlowSimulation -alarm=400  -emit_protected -lv LOG_STATS
LOG_STDOUT        | info    | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Resources/Data/DHC/Loads/Examples/MediumOffice-90.1-2010-5A.mos"
LOG_STDOUT        | info    | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Resources/Data/DHC/Loads/Examples/MediumOffice-90.1-2010-5A.mos"
LOG_STDOUT        | info    | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Resources/Data/DHC/Loads/Examples/MediumOffice-90.1-2010-5A.mos"
LOG_ASSERT        | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable]
|                 | |       | The following assertion has been violated at time 15724800.000000
|                 | |       | ((pla.valByp.m_flow >= 0.0 and pla.valByp.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= pla.valByp.m_flow <= 1e5, has value: -0.189856"
LOG_ASSERT        | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable]
|                 | |       | The following assertion has been violated at time 15724800.000000
|                 | |       | ((pla.pumCHW.pum[2].etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumCHW.pum[2].etaHyd, has value: -7.14296e-22"
LOG_ASSERT        | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable]
|                 | |       | The following assertion has been violated at time 15724800.000000
|                 | |       | ((pla.pumCHW.pum[1].etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumCHW.pum[1].etaHyd, has value: -7.14296e-22"
LOG_SUCCESS       | info    | The initialization finished successfully with 3 homotopy steps.
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Fluid/HeatExchangers/CoolingTowers/BaseClasses/Merkel.mo:93:3-94:53:writable]
|                 | |       | The following assertion has been violated at time 15724830.001572
|                 | |       | ((pla.cooTowWitByp.cooTowSys.cooTow[1].per.FRWat >= 0.0 and pla.cooTowWitByp.cooTowSys.cooTow[1].per.FRWat <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= pla.cooTowWitByp.cooTowSys.cooTow[1].per.FRWat <= 1.0, has value: 1.99992"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable]
|                 | |       | The following assertion has been violated at time 15725009.473910
|                 | |       | ((buiETS[2].bui.disFloCoo.pumFlo.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= buiETS[2].bui.disFloCoo.pumFlo.etaHyd, has value: -0.0448585"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable]
|                 | |       | The following assertion has been violated at time 15725009.473910
|                 | |       | ((buiETS[1].bui.disFloCoo.pumFlo.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= buiETS[1].bui.disFloCoo.pumFlo.eff.yMot, has value: -0.000199259"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable]
|                 | |       | The following assertion has been violated at time 15725767.680000
|                 | |       | ((buiETS[3].bui.disFloCoo.pumFlo.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= buiETS[3].bui.disFloCoo.pumFlo.eff.yMot, has value: -0.0166588"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable]
|                 | |       | The following assertion has been violated at time 15725767.680000
|                 | |       | ((buiETS[2].bui.disFloCoo.pumFlo.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= buiETS[2].bui.disFloCoo.pumFlo.eff.yMot, has value: -0.0182711"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68:3-73:35:writable]
|                 | |       | The following assertion has been violated at time 15742892.820294
|                 | |       | ((buiETS[3].bui.terUniCoo.hexWetNtu.SHR >= 0.0 and buiETS[3].bui.terUniCoo.hexWetNtu.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= buiETS[3].bui.terUniCoo.hexWetNtu.SHR <= 1.0, has value: -4.28186e-14"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable]
|                 | |       | The following assertion has been violated at time 15742892.820294
|                 | |       | ((buiETS[3].bui.disFloCoo.pumFlo.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= buiETS[3].bui.disFloCoo.pumFlo.etaHyd, has value: -0.000213743"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68:3-73:35:writable]
|                 | |       | The following assertion has been violated at time 15742892.820294
|                 | |       | ((buiETS[2].bui.terUniCoo.hexWetNtu.SHR >= 0.0 and buiETS[2].bui.terUniCoo.hexWetNtu.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= buiETS[2].bui.terUniCoo.hexWetNtu.SHR <= 1.0, has value: -4.29015e-14"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68:3-73:35:writable]
|                 | |       | The following assertion has been violated at time 15742892.820294
|                 | |       | ((buiETS[1].bui.terUniCoo.hexWetNtu.SHR >= 0.0 and buiETS[1].bui.terUniCoo.hexWetNtu.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= buiETS[1].bui.terUniCoo.hexWetNtu.SHR <= 1.0, has value: -4.29498e-14"
LOG_ASSERT        | info    | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable]
|                 | |       | The following assertion has been violated at time 15742892.820294
|                 | |       | ((buiETS[1].bui.disFloCoo.pumFlo.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= buiETS[1].bui.disFloCoo.pumFlo.etaHyd, has value: -0.000213764"