Environment - simulationEnvironment: startTime=1.57248e+07 stopTime=1.63296e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=241.92 Regular simulation: ./Buildings_12_Buildings.DHC.Examples.Cooling.ElectricChillersDirectETS -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Resources/Data/DHC/Loads/Examples/MediumOffice-90.1-2010-5A.mos" LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Resources/Data/DHC/Loads/Examples/MediumOffice-90.1-2010-5A.mos" LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Resources/Data/DHC/Loads/Examples/MediumOffice-90.1-2010-5A.mos" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 15724800.000000 | | | | ((pla.valByp.m_flow >= 0.0 and pla.valByp.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= pla.valByp.m_flow <= 1e5, has value: -0.189856" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 15724800.000000 | | | | ((pla.pumCHW.pum[2].etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumCHW.pum[2].etaHyd, has value: -7.14296e-22" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 15724800.000000 | | | | ((pla.pumCHW.pum[1].etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumCHW.pum[1].etaHyd, has value: -7.14296e-22" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Fluid/HeatExchangers/CoolingTowers/BaseClasses/Merkel.mo:93:3-94:53:writable] | | | | The following assertion has been violated at time 15724830.001572 | | | | ((pla.cooTowWitByp.cooTowSys.cooTow[1].per.FRWat >= 0.0 and pla.cooTowWitByp.cooTowSys.cooTow[1].per.FRWat <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= pla.cooTowWitByp.cooTowSys.cooTow[1].per.FRWat <= 1.0, has value: 1.99992" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 15725009.473910 | | | | ((buiETS[2].bui.disFloCoo.pumFlo.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= buiETS[2].bui.disFloCoo.pumFlo.etaHyd, has value: -0.0448585" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 15725009.473910 | | | | ((buiETS[1].bui.disFloCoo.pumFlo.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= buiETS[1].bui.disFloCoo.pumFlo.eff.yMot, has value: -0.000199259" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 15725767.680000 | | | | ((buiETS[3].bui.disFloCoo.pumFlo.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= buiETS[3].bui.disFloCoo.pumFlo.eff.yMot, has value: -0.0166588" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 15725767.680000 | | | | ((buiETS[2].bui.disFloCoo.pumFlo.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= buiETS[2].bui.disFloCoo.pumFlo.eff.yMot, has value: -0.0182711" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68:3-73:35:writable] | | | | The following assertion has been violated at time 15742892.820294 | | | | ((buiETS[3].bui.terUniCoo.hexWetNtu.SHR >= 0.0 and buiETS[3].bui.terUniCoo.hexWetNtu.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= buiETS[3].bui.terUniCoo.hexWetNtu.SHR <= 1.0, has value: -4.28186e-14" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 15742892.820294 | | | | ((buiETS[3].bui.disFloCoo.pumFlo.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= buiETS[3].bui.disFloCoo.pumFlo.etaHyd, has value: -0.000213743" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68:3-73:35:writable] | | | | The following assertion has been violated at time 15742892.820294 | | | | ((buiETS[2].bui.terUniCoo.hexWetNtu.SHR >= 0.0 and buiETS[2].bui.terUniCoo.hexWetNtu.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= buiETS[2].bui.terUniCoo.hexWetNtu.SHR <= 1.0, has value: -4.29015e-14" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68:3-73:35:writable] | | | | The following assertion has been violated at time 15742892.820294 | | | | ((buiETS[1].bui.terUniCoo.hexWetNtu.SHR >= 0.0 and buiETS[1].bui.terUniCoo.hexWetNtu.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= buiETS[1].bui.terUniCoo.hexWetNtu.SHR <= 1.0, has value: -4.29498e-14" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.1-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 15742892.820294 | | | | ((buiETS[1].bui.disFloCoo.pumFlo.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= buiETS[1].bui.disFloCoo.pumFlo.etaHyd, has value: -0.000213764"