Environment - simulationEnvironment: startTime=0 stopTime=604800 tolerance=1e-06 numberOfIntervals=10080 stepSize=60 Regular simulation: ./BuildingSystems_BuildingSystems.ThermalZones.ReducedOrder.Validation.RoomWithoutLatentGain -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not senRelHum.warnAboutOnePortConnection)) --> "Sensor RoomWithoutLatentGain.senRelHum can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'BuildingSystems.Fluid.MixingVolumes`. | | | | See BuildingSystems.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in RoomWithoutLatentGain.senRelHum." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not senMasFra.warnAboutOnePortConnection)) --> "Sensor RoomWithoutLatentGain.senMasFra can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'BuildingSystems.Fluid.MixingVolumes`. | | | | See BuildingSystems.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in RoomWithoutLatentGain.senMasFra." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0110795s reading init.xml | | | | | | 0.000898525s reading info.xml | | | | | | 9.1311e-05s [ 0.1%] pre-initialization | | | | | | 0.000206337s [ 0.1%] initialization | | | | | | 5.861e-06s [ 0.0%] steps | | | | | | 0.0152124s [ 10.6%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00736565s [ 5.1%] event-handling | | | | | | 0.0106216s [ 7.4%] overhead | | | | | | 0.109577s [ 76.6%] simulation | | | | | | 0.14308s [100.0%] total | | | | | events | | | | | | 167 state events | | | | | | 168 time events | | | | | solver: dassl | | | | | | 13307 steps taken | | | | | | 16155 calls of functionODE | | | | | | 8066 evaluations of jacobian | | | | | | 240 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0441376s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.