Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0004 Regular simulation: ./BuildingSystems_BuildingSystems.Fluid.Movers.Examples.MoverStages -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump_m_flow.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in MoverStages.pump_m_flow: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-426:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (pump_m_flow.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pump_m_flow.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in MoverStages.pump_m_flow: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:428:3-437:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump_m_flow.per.haveWMot_nominal or not (pump_m_flow.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pump_m_flow.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in MoverStages.pump_m_flow: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0195762s reading init.xml | | | | | | 0.00179892s reading info.xml | | | | | | 8.1573e-05s [ 0.2%] pre-initialization | | | | | | 0.00067763s [ 2.0%] initialization | | | | | | 4.299e-06s [ 0.0%] steps | | | | | | 7.935e-06s [ 0.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000550737s [ 1.6%] event-handling | | | | | | 0.0077033s [ 22.7%] overhead | | | | | | 0.0249388s [ 73.4%] simulation | | | | | | 0.0339643s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 9505 steps taken | | | | | | 9505 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.