Environment - simulationEnvironment: startTime=0 stopTime=3600 tolerance=1e-06 numberOfIntervals=2500 stepSize=1.44 Regular simulation: ./BuildingSystems_BuildingSystems.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Interfaces/PartialFourPortInterface.mo:23:3-24:84:writable] | | | | The following assertion has been violated at time 1831.680000 | | | | ((chi.m1_flow >= 0.0 and chi.m1_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= chi.m1_flow <= 1e5, has value: -1.90152e-15" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00471107s reading init.xml | | | | | | 0.000479669s reading info.xml | | | | | | 5.1416e-05s [ 0.4%] pre-initialization | | | | | | 0.000156614s [ 1.1%] initialization | | | | | | 1.453e-06s [ 0.0%] steps | | | | | | 1.1625e-05s [ 0.1%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 6.9503e-05s [ 0.5%] event-handling | | | | | | 0.00397024s [ 27.4%] overhead | | | | | | 0.0102536s [ 70.6%] simulation | | | | | | 0.0145145s [100.0%] total | | | | | events | | | | | | 4 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 18513 steps taken | | | | | | 18513 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.