Environment - simulationEnvironment: startTime=0 stopTime=3.1536e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=12614.4 Regular simulation: ./BuildingSystems_BuildingSystems.Applications.HeatingSystems.SolarHeatingSystem -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/weather/Germany_Berlin.txt" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump1.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in SolarHeatingSystem.pump1: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-426:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (pump1.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pump1.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in SolarHeatingSystem.pump1: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:428:3-437:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump1.per.haveWMot_nominal or not (pump1.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pump1.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in SolarHeatingSystem.pump1: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump2.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in SolarHeatingSystem.pump2: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-426:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (pump2.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pump2.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in SolarHeatingSystem.pump2: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:428:3-437:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump2.per.haveWMot_nominal or not (pump2.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pump2.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in SolarHeatingSystem.pump2: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Ambience.mo:175:3-177:124:writable] | | | | The following assertion has been violated at time 1166832.000000 | | | | ((ambience.cloudCover >= 0.0 and ambience.cloudCover <= 8.0)) --> "Variable violating min/max constraint: 0.0 <= ambience.cloudCover <= 8.0, has value: 8.2356" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/WeatherData/BaseClasses/WeatherDataFileGeneral.mo:16:3-17:24:writable] | | | | The following assertion has been violated at time 6414422.400000 | | | | ((ambience.weatherDataReader.weatherData.phiAir >= 0.0 and ambience.weatherDataReader.weatherData.phiAir <= 1.01)) --> "Variable violating min/max constraint: 0.0 <= ambience.weatherDataReader.weatherData.phiAir <= 1.01, has value: 1.01016" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:18:3-18:68:writable] | | | | The following assertion has been violated at time 13030675.200000 | | | | ((building.surfacesToAmbience.surface[1].x >= 0.0 and building.surfacesToAmbience.surface[1].x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= building.surfacesToAmbience.surface[1].x <= 1.0, has value: -4.97466e-19" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:18:3-18:68:writable] | | | | The following assertion has been violated at time 13030675.200000 | | | | ((building.surfacesToAmbience.surface[2].x >= 0.0 and building.surfacesToAmbience.surface[2].x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= building.surfacesToAmbience.surface[2].x <= 1.0, has value: -4.97466e-19" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:18:3-18:68:writable] | | | | The following assertion has been violated at time 13030675.200000 | | | | ((building.surfacesToAmbience.surface[3].x >= 0.0 and building.surfacesToAmbience.surface[3].x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= building.surfacesToAmbience.surface[3].x <= 1.0, has value: -4.97466e-19" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:18:3-18:68:writable] | | | | The following assertion has been violated at time 13030675.200000 | | | | ((building.surfacesToAmbience.surface[4].x >= 0.0 and building.surfacesToAmbience.surface[4].x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= building.surfacesToAmbience.surface[4].x <= 1.0, has value: -4.97466e-19" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:18:3-18:68:writable] | | | | The following assertion has been violated at time 13030675.200000 | | | | ((building.surfacesToAmbience.surface[5].x >= 0.0 and building.surfacesToAmbience.surface[5].x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= building.surfacesToAmbience.surface[5].x <= 1.0, has value: -4.97466e-19" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:18:3-18:68:writable] | | | | The following assertion has been violated at time 13030675.200000 | | | | ((building.surfacesToAmbience.surface[6].x >= 0.0 and building.surfacesToAmbience.surface[6].x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= building.surfacesToAmbience.surface[6].x <= 1.0, has value: -5.49973e-20" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:18:3-18:68:writable] | | | | The following assertion has been violated at time 13030675.200000 | | | | ((building.surfacesToAmbience.surface[7].x >= 0.0 and building.surfacesToAmbience.surface[7].x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= building.surfacesToAmbience.surface[7].x <= 1.0, has value: -4.97466e-19" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:18:3-18:68:writable] | | | | The following assertion has been violated at time 13030675.200000 | | | | ((building.surfacesToAmbience.surface[8].x >= 0.0 and building.surfacesToAmbience.surface[8].x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= building.surfacesToAmbience.surface[8].x <= 1.0, has value: -5.49973e-20" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:18:3-18:68:writable] | | | | The following assertion has been violated at time 13030675.200000 | | | | ((building.surfacesToAmbience.surface[9].x >= 0.0 and building.surfacesToAmbience.surface[9].x <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= building.surfacesToAmbience.surface[9].x <= 1.0, has value: -4.97466e-19" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.158506s reading init.xml | | | | | | 0.0133578s reading info.xml | | | | | | 0.000430116s [ 0.0%] pre-initialization | | | | | | 0.00735335s [ 0.0%] initialization | | | | | | 0.00359928s [ 0.0%] steps | | | | | | 17.8414s [ 5.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 70.4864s [ 19.8%] event-handling | | | | | | 0.126872s [ 0.0%] overhead | | | | | | 267.41s [ 75.1%] simulation | | | | | | 355.876s [100.0%] total | | | | | events | | | | | | 1015 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 1371577 steps taken | | | | | | 2000090 calls of functionODE | | | | | | 155787 evaluations of jacobian | | | | | | 98564 error test failures | | | | | | 16 convergence test failures | | | | | | 157.275s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.