Environment - simulationEnvironment: startTime=0 stopTime=3.1536e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=12614.4 Regular simulation: ./BuildingSystems_BuildingSystems.Applications.HeatingSystems.HeatPumpHeatingSystem -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/weather/Germany_Berlin.txt" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPumpHeatingSystem.pump: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-426:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (pump.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pump.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in HeatPumpHeatingSystem.pump: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:428:3-437:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump.per.haveWMot_nominal or not (pump.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pump.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in HeatPumpHeatingSystem.pump: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Ambience.mo:175:3-177:124:writable] | | | | The following assertion has been violated at time 1166832.000000 | | | | ((ambience.cloudCover >= 0.0 and ambience.cloudCover <= 8.0)) --> "Variable violating min/max constraint: 0.0 <= ambience.cloudCover <= 8.0, has value: 8.2356" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/WeatherData/BaseClasses/WeatherDataFileGeneral.mo:16:3-17:24:writable] | | | | The following assertion has been violated at time 6414422.400000 | | | | ((ambience.weatherDataReader.weatherData.phiAir >= 0.0 and ambience.weatherDataReader.weatherData.phiAir <= 1.01)) --> "Variable violating min/max constraint: 0.0 <= ambience.weatherDataReader.weatherData.phiAir <= 1.01, has value: 1.01016" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.114401s reading init.xml | | | | | | 0.00876157s reading info.xml | | | | | | 0.000325189s [ 0.0%] pre-initialization | | | | | | 0.00618127s [ 0.0%] initialization | | | | | | 0.0036512s [ 0.0%] steps | | | | | | 1.16493s [ 2.5%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 10.514s [ 22.2%] event-handling | | | | | | 0.0726837s [ 0.2%] overhead | | | | | | 35.5281s [ 75.1%] simulation | | | | | | 47.2898s [100.0%] total | | | | | events | | | | | | 521 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 216433 steps taken | | | | | | 312040 calls of functionODE | | | | | | 23822 evaluations of jacobian | | | | | | 12841 error test failures | | | | | | 82 convergence test failures | | | | | | 20.6559s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.