Environment - simulationEnvironment: startTime=0 stopTime=3.1536e+07 tolerance=1e-06 numberOfIntervals=8760 stepSize=3600 Regular simulation: ./Annex60_1.0.0_Annex60.ThermalZones.ReducedOrder.Examples.SimpleRoomThreeElements -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/Resources/weatherdata/USA_CA_San.Francisco.Intl.AP.724940_TMY3.mos" LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/Resources/weatherdata/USA_CA_San.Francisco.Intl.AP.724940_TMY3.mos" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/BoundaryConditions/WeatherData/ReaderTMY3.mo:314:3-317:56:writable] | | | | The following assertion has been violated at time 14400.000001 | | | | ((weaDat.totSkyCov_in_internal >= 0.0 and weaDat.totSkyCov_in_internal <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= weaDat.totSkyCov_in_internal <= 1.0, has value: -2.4003e-11" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/BoundaryConditions/WeatherData/ReaderTMY3.mo:318:3-321:56:writable] | | | | The following assertion has been violated at time 14400.000001 | | | | ((weaDat.opaSkyCov_in_internal >= 0.0 and weaDat.opaSkyCov_in_internal <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= weaDat.opaSkyCov_in_internal <= 1.0, has value: -2.4003e-11" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/BoundaryConditions/WeatherData/ReaderTMY3.mo:692:3-697:29:writable] | | | | The following assertion has been violated at time 514800.000051 | | | | ((HDifTil[1].weaBus.nOpa >= 0.0 and HDifTil[1].weaBus.nOpa <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= HDifTil[1].weaBus.nOpa <= 1.0, has value: 1" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/BoundaryConditions/WeatherData/ReaderTMY3.mo:686:3-691:29:writable] | | | | The following assertion has been violated at time 514800.000051 | | | | ((HDifTil[1].weaBus.nTot >= 0.0 and HDifTil[1].weaBus.nTot <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= HDifTil[1].weaBus.nTot <= 1.0, has value: 1" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/BoundaryConditions/WeatherData/ReaderTMY3.mo:334:3-337:56:writable] | | | | The following assertion has been violated at time 529200.000053 | | | | ((weaDat.relHum_in_internal >= 0.0 and weaDat.relHum_in_internal <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= weaDat.relHum_in_internal <= 1.0, has value: 1" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0148272s reading init.xml | | | | | | 0.00141945s reading info.xml | | | | | | 0.000102181s [ 0.0%] pre-initialization | | | | | | 0.0265047s [ 0.6%] initialization | | | | | | 0.000438221s [ 0.0%] steps | | | | | | 0.248186s [ 5.4%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.159358s [ 3.5%] event-handling | | | | | | 0.044675s [ 1.0%] overhead | | | | | | 4.13546s [ 89.6%] simulation | | | | | | 4.61473s [100.0%] total | | | | | events | | | | | | 8395 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 261286 steps taken | | | | | | 412378 calls of functionODE | | | | | | 107638 evaluations of jacobian | | | | | | 25003 error test failures | | | | | | 0 convergence test failures | | | | | | 2.03005s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.