Environment - simulationEnvironment: startTime=0 stopTime=7200 tolerance=1e-06 numberOfIntervals=480 stepSize=15 Regular simulation: ./AixLib_latest_AixLib.Systems.ModularAHU.Examples.EONERC_AHU2 -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((genericAHU.fanSup.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((genericAHU.fanRet.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Fluid/Actuators/BaseClasses/ActuatorSignal.mo:31:3-33:69:writable] | | | | The following assertion has been violated at time 52.500000 | | | | ((genericAHU.preheater.hydraulicModule.valve.y_actual >= 0.0 and genericAHU.preheater.hydraulicModule.valve.y_actual <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= genericAHU.preheater.hydraulicModule.valve.y_actual <= 1.0, has value: -4.45533e-18" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Fluid/Actuators/BaseClasses/ActuatorSignal.mo:31:3-33:69:writable] | | | | The following assertion has been violated at time 1147.500000 | | | | ((genericAHU.cooler.hydraulicModule.valve.y_actual >= 0.0 and genericAHU.cooler.hydraulicModule.valve.y_actual <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= genericAHU.cooler.hydraulicModule.valve.y_actual <= 1.0, has value: -6.33921e-18" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.224644s reading init.xml | | | | | | 0.0196956s reading info.xml | | | | | | 0.000661771s [ 0.0%] pre-initialization | | | | | | 0.00327196s [ 0.0%] initialization | | | | | | 0.0276019s [ 0.1%] steps | | | | | | 3.77637s [ 19.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 1.15705s [ 5.9%] event-handling | | | | | | 0.0385655s [ 0.2%] overhead | | | | | | 14.695s [ 74.6%] simulation | | | | | | 19.6985s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 17369 steps taken | | | | | | 38629 calls of functionODE | | | | | | 14676 evaluations of jacobian | | | | | | 1122 error test failures | | | | | | 3946 convergence test failures | | | | | | 12.3367s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.