Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-07 numberOfIntervals=1440 stepSize=60 Regular simulation: ./AixLib_latest_AixLib.Fluid.DistrictHeatingCooling.Demands.Examples.DHCSubstationHeatPumpChiller -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((DHCsubstationHeatingDirectCooling.pumHea.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((DHCsubstationHeatingDirectCooling.pumCoo.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0218124s reading init.xml | | | | | | 0.00199232s reading info.xml | | | | | | 0.000102352s [ 0.2%] pre-initialization | | | | | | 0.000348373s [ 0.9%] initialization | | | | | | 7.674e-06s [ 0.0%] steps | | | | | | 0.00132855s [ 3.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000431721s [ 1.1%] event-handling | | | | | | 0.00913322s [ 22.3%] overhead | | | | | | 0.0295918s [ 72.3%] simulation | | | | | | 0.0409437s [100.0%] total | | | | | events | | | | | | 5 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 529 steps taken | | | | | | 653 calls of functionODE | | | | | | 120 evaluations of jacobian | | | | | | 13 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00114684s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.