Environment - simulationEnvironment: startTime=0 stopTime=29600 tolerance=1e-06 numberOfIntervals=29600 stepSize=1 Regular simulation: ./AixLib_AixLib.Fluid.MassExchangers.MembraneBasedEnthalpyExchangers.Validation.StaticValidation -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_STDOUT | info | ... loading "Boundary" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Resources/Fluid/MembraneBasedEnthalpyExchanger/StaticValidationEta.txt" LOG_STDOUT | info | ... loading "Boundary" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Resources/Fluid/MembraneBasedEnthalpyExchanger/StaticValidationOda.txt" LOG_STDOUT | info | ... loading "Result" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Resources/Fluid/MembraneBasedEnthalpyExchanger/StaticValidationResult.txt" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((fan.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((fan1.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Fluid/Sensors/RelativeHumidityTwoPort.mo:5:3-11:26:writable] | | | | The following assertion has been violated at time 4810.500000 | | | | ((enthalpyExchanger.airDuct1.senRelHum.phi >= 0.01 and enthalpyExchanger.airDuct1.senRelHum.phi <= 0.99)) --> "Variable violating min/max constraint: 0.01 <= enthalpyExchanger.airDuct1.senRelHum.phi <= 0.99, has value: 0.991497" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.097546s reading init.xml | | | | | | 0.0081151s reading info.xml | | | | | | 0.000381475s [ 0.0%] pre-initialization | | | | | | 0.0107877s [ 0.1%] initialization | | | | | | 0.000148589s [ 0.0%] steps | | | | | | 0.279202s [ 1.7%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0545521s [ 0.3%] event-handling | | | | | | 0.498282s [ 3.1%] overhead | | | | | | 15.1364s [ 94.7%] simulation | | | | | | 15.9798s [100.0%] total | | | | | events | | | | | | 72 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 7377 steps taken | | | | | | 10149 calls of functionODE | | | | | | 1169 evaluations of jacobian | | | | | | 220 error test failures | | | | | | 1 convergence test failures | | | | | | 3.41279s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.