(cd run_fmpy-fmi3-cs-cvode && python3 -m fmpy simulate --output-file ../PowerGrids_dev_PowerGrids.Examples.Tutorial.GridOperation.Controlled.ControlledGridWithoutPSS_fmpy-fmi3-cs-cvode_res.csv --start-time 0 --stop-time 10 --timeout 240 --relative-tolerance 1e-06 --interface-type CoSimulation --output-interval 0.02 ../PowerGrids_dev_PowerGrids_Examples_Tutorial_GridOperation_Controlled_ControlledGridWithoutPSS_fmpy-fmi3-cs-cvode.fmu) LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 2.000000 | | | | ((GEN.VPuCheck > GEN.VPuMin), GEN.VPuCheck=0.4096172948004655, GEN.VPuMin=0.7) --> "Voltage too low (VPu=0.409617 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:35:5-35:162:writable] | | | | The following assertion has been violated at time 2.000000 | | | | ((GEN.IPuCheck < GEN.IPuMax), GEN.IPuCheck=2.561538534804007, GEN.IPuMax=2.5) --> "Current too high (IPu=2.56154 > 2.5), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 2.000000 | | | | ((NTLV.VPuCheck > NTLV.VPuMin), NTLV.VPuCheck=0.4096172948004655, NTLV.VPuMin=0.7) --> "Voltage too low (VPu=0.409617 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 2.000000 | | | | ((GRID.VPuCheck > GRID.VPuMin), GRID.VPuCheck=0.001211586289823361, GRID.VPuMin=0.7) --> "Voltage too low (VPu=0.00121159 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:35:5-35:162:writable] | | | | The following assertion has been violated at time 2.000000 | | | | ((GRID.IPuCheck < GRID.IPuMax), GRID.IPuCheck=4.772519510853434, GRID.IPuMax=2.5) --> "Current too high (IPu=4.77252 > 2.5), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 2.000000 | | | | ((GRIDL.VPuCheck > GRIDL.VPuMin), GRIDL.VPuCheck=0.001211586289823361, GRIDL.VPuMin=0.7) --> "Voltage too low (VPu=0.00121159 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 2.000000 | | | | ((FAULT.VPuCheck > FAULT.VPuMin), FAULT.VPuCheck=0.001211586289823361, FAULT.VPuMin=0.7) --> "Voltage too low (VPu=0.00121159 < 0.7), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:35:5-35:162:writable] | | | | The following assertion has been violated at time 2.000000 | | | | ((FAULT.IPuCheck < FAULT.IPuMax), FAULT.IPuCheck=6.998122410012302, FAULT.IPuMax=2.5) --> "Current too high (IPu=6.99812 > 2.5), check if the numerical solution is valid"