(cd run_fmpy-fmi3-cs-cvode && python3 -m fmpy simulate --output-file ../PowerGrids_dev_PowerGrids.Electrical.Test.TestTransformerWithTapChangerMax_fmpy-fmi3-cs-cvode_res.csv --start-time 0 --stop-time 80 --timeout 240 --relative-tolerance 1e-06 --interface-type CoSimulation --output-interval 0.16 ../PowerGrids_dev_PowerGrids_Electrical_Test_TestTransformerWithTapChangerMax_fmpy-fmi3-cs-cvode.fmu) LOG_STDOUT | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 23.360000 | | | | ((bus.VPuCheck > bus.VPuMin), bus.VPuCheck=0.1993948087687695, bus.VPuMin=0.2) --> "Voltage too low (VPu=0.199395 < 0.2), check if the numerical solution is valid" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/SolutionChecking.mo:34:5-34:161:writable] | | | | The following assertion has been violated at time 24.160000 | | | | ((infiniteBus.VPuCheck > infiniteBus.VPuMin), infiniteBus.VPuCheck=0.1967992024450649, infiniteBus.VPuMin=0.2) --> "Voltage too low (VPu=0.196799 < 0.2), check if the numerical solution is valid"