(cd run_fmpy-fmi3-cs-cvode && python3 -m fmpy simulate --output-file ../Buildings_13_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Spring_fmpy-fmi3-cs-cvode_res.csv --start-time 7.344e+06 --stop-time 7.776e+06 --timeout 450 --relative-tolerance 1e-07 --interface-type CoSimulation --output-interval 172.8 ../Buildings_13_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SmallOffice_Guideline36Spring_fmpy-fmi3-cs-cvode.fmu) EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.11.17 06:14 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 03/27/2006 for SPAWN-RUNPERIOD LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 7367700.000000 | | | | ((hvac.conVAV[1].ala.not2.y), hvac.conVAV[1].ala.not2.y=false) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 7367700.000000 | | | | ((hvac.conVAV[2].ala.not1.y), hvac.conVAV[2].ala.not1.y=false) --> "Warning: airflow is less than 50% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 7367700.000000 | | | | ((hvac.conVAV[2].ala.not2.y), hvac.conVAV[2].ala.not2.y=false) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 7367700.000000 | | | | ((hvac.conVAV[3].ala.not2.y), hvac.conVAV[3].ala.not2.y=false) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 7367700.000000 | | | | ((hvac.conVAV[4].ala.not1.y), hvac.conVAV[4].ala.not1.y=false) --> "Warning: airflow is less than 50% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 7367700.000000 | | | | ((hvac.conVAV[4].ala.not2.y), hvac.conVAV[4].ala.not2.y=false) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 7367700.000000 | | | | ((hvac.conVAV[5].ala.not2.y), hvac.conVAV[5].ala.not2.y=false) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 7625100.000000 | | | | ((hvac.conVAV[5].ala.not1.y), hvac.conVAV[5].ala.not1.y=false) --> "Warning: airflow is less than 50% of the setpoint." Writing final SQL reports EnergyPlus Run Time=00hr 00min 10.15sec EnergyPlus Completed Successfully.