(cd run_fmpy-fmi3-cs-cvode && python3 -m fmpy simulate --output-file ../Buildings_12_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.ASHRAE2006Spring_fmpy-fmi3-cs-cvode_res.csv --output-variables flo.sou.TAir flo.eas.TAir flo.nor.TAir flo.wes.TAir flo.cor.TAir hvac.TSetRoo.setPoiHea.y hvac.TSetRoo.setPoiCoo.y hvac.fanSup.y 'hvac.VAVBox[5].vav.y_actual' 'hvac.VAVBox[1].vav.y_actual' 'hvac.VAVBox[2].vav.y_actual' 'hvac.VAVBox[3].vav.y_actual' 'hvac.VAVBox[4].vav.y_actual' hvac.damOut.y 'hvac.VAVBox[1].TSup' 'hvac.VAVBox[2].TSup' 'hvac.VAVBox[3].TSup' 'hvac.VAVBox[4].TSup' 'hvac.VAVBox[5].TSup' hvac.res.EFan hvac.res.EHea hvac.res.ECoo --start-time 7.344e+06 --stop-time 7.776e+06 --timeout 240 --relative-tolerance 1e-07 --interface-type CoSimulation --output-interval 172.8 ../Buildings_12_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SmallOffice_ASHRAE2006Spring_fmpy-fmi3-cs-cvode.fmu) EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.11.17 06:55 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 03/27/2006 for SPAWN-RUNPERIOD Writing final SQL reports EnergyPlus Run Time=00hr 00min 2.71sec EnergyPlus Completed Successfully.