(cd run_fmpy-fmi3-cs-cvode && python3 -m fmpy simulate --output-file ../Buildings_12_Buildings.Fluid.DXSystems.Cooling.AirSource.Validation.SingleSpeedPLR_fmpy-fmi3-cs-cvode_res.csv --output-variables TOutDegC.Celsius TOutEPlu.y sinSpeDX.m_flow XEvaOutMea.y XEvaOutEPluMod.y Q_flowMea.y Q_flowEPlu.y PMea.y PEPlu.y --start-time 0 --stop-time 86400 --timeout 240 --relative-tolerance 1e-06 --interface-type CoSimulation --output-interval 34.56 ../Buildings_12_Buildings_Fluid_DXSystems_Cooling_AirSource_Validation_SingleSpeedPLR_fmpy-fmi3-cs-cvode.fmu) LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.3-maint.12.x/Fluid/DXSystems/Cooling/BaseClasses/PartialCapacity.mo:121:7-134:38:writable] | | | | The following assertion has been violated at time 25200.000000 | | | | ((not (sinSpeDX.dxCoi.TEvaIn > sinSpeDX.dxCoi.dryCoi.coiCap.sta[1].perCur.TEvaInMax or sinSpeDX.dxCoi.TEvaIn < sinSpeDX.dxCoi.dryCoi.coiCap.sta[1].perCur.TEvaInMin)), sinSpeDX.dxCoi.TEvaIn=297.23651629, sinSpeDX.dxCoi.dryCoi.coiCap.sta[1].perCur.TEvaInMax=297.03889, sinSpeDX.dxCoi.dryCoi.coiCap.sta[1].perCur.TEvaInMin=285.92778) --> "*** Warning: Evaporator temperature TEvaIn is out of bounds in DX coil model at time = 25200. | | | | stage = 1 | | | | TEvaInMin = 285.928 Kelvin (12.7778 degC) | | | | TEvaIn = 297.237 Kelvin (24.0865 degC) | | | | TEvaInMax = 297.039 Kelvin (23.8889 degC) | | | | Extrapolation can introduce large errors. | | | | This warning will only be reported once for each stage."