Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr SiemensPower_SiemensPower.Components.HeatExchanger.Tests.ParallelFlowEvaporatorOwnMedia_testsimple.conf.json Using package SiemensPower with version 2.2 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/package.mo) Using package ModelicaServices with version 3.2.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo) Using package Modelica with version 3.2.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo) Using package Complex with version 3.2.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo) Running command: "" <> buildModelFMU(SiemensPower.Components.HeatExchanger.Tests.ParallelFlowEvaporatorOwnMedia_testsimple,fileNamePrefix="SiemensPower_SiemensPower_Components_HeatExchanger_Tests_ParallelFlowEvaporatorOwnMedia_testsimple",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo): time 0.01435/0.01435, allocations: 163.6 kB / 15.12 MB, free: 5.953 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo): time 1.807/1.807, allocations: 170.8 MB / 186.7 MB, free: 1.113 MB / 154.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo): time 0.001761/0.001761, allocations: 102.8 kB / 226.2 MB, free: 10.09 MB / 186.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/package.mo): time 0.0426/0.0426, allocations: 5.567 MB / 271.2 MB, free: 13 MB / 234.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0004801/0.0004802, allocations: 12 kB / 321.8 MB, free: 60.33 MB / 250.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.07471/0.07522, allocations: 40.04 MB / 361.9 MB, free: 20.32 MB / 250.7 MB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/Components/HeatExchanger/Tests/ParallelFlowEvaporatorOwnMedia_testsimple.mo:32:7-32:20:writable] Error: Modified element use_h_in not found in class WaterSourceMH. Notification: Performance of FrontEnd: time 0.003365/0.07865, allocations: 1.888 MB / 363.8 MB, free: 18.41 MB / 250.7 MB