OMSimulator -r=Modelica_3.2.2_cs_Modelica.Fluid.Examples.Tanks.EmptyTanks_res.mat --tempDir=temp_Modelica_3_2_2_cs_Modelica_Fluid_Examples_Tanks_EmptyTanks_fmu --startTime=0 --stopTime=50 --timeout=50 --tolerance=1e-06 Modelica_3_2_2_cs_Modelica_Fluid_Examples_Tanks_EmptyTanks.fmu info: Set temp directory to "/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/Modelica_3.2.2_cs_Modelica.Fluid.Examples.Tanks.EmptyTanks" info: Set working directory to "/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/Modelica_3.2.2_cs_Modelica.Fluid.Examples.Tanks.EmptyTanks" info: New temp directory has been created: "temp_Modelica_3_2_2_cs_Modelica_Fluid_Examples_Tanks_EmptyTanks_fmu" info: Set temp directory to "/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/Modelica_3.2.2_cs_Modelica.Fluid.Examples.Tanks.EmptyTanks/temp_Modelica_3_2_2_cs_Modelica_Fluid_Examples_Tanks_EmptyTanks_fmu" info: Set working directory to "/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/Modelica_3.2.2_cs_Modelica.Fluid.Examples.Tanks.EmptyTanks" info: New model "model" with corresponding temp directory "/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/Modelica_3.2.2_cs_Modelica.Fluid.Examples.Tanks.EmptyTanks/temp_Modelica_3_2_2_cs_Modelica_Fluid_Examples_Tanks_EmptyTanks_fmu/model-pipxmhc4" info: Result file: Modelica_3.2.2_cs_Modelica.Fluid.Examples.Tanks.EmptyTanks_res.mat (bufferSize=1) warning: fmu (logStatusWarning): /var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Media/package.mo:6382: The following assertion has been violated at time 0.505051 tank2.medium.T >= 272.15 and tank2.medium.T <= 403.15 assert | error | | | | | Temperature T (= 1.22341e+06 K) is not | | | | in the allowed range (272.15 K <= T <= 403.15 K) | | | | required from medium model "SimpleLiquidWater". error: [fmi2logger] fmu (logFmi2Call): fmi2CompletedIntegratorStep: terminated by an assertion. warning: fmu (logStatusWarning): /var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Media/package.mo:6382: The following assertion has been violated at time 0.505051 tank2.medium.T >= 272.15 and tank2.medium.T <= 403.15 assert | error | | | | | Temperature T (= 1.22341e+06 K) is not | | | | in the allowed range (272.15 K <= T <= 403.15 K) | | | | required from medium model "SimpleLiquidWater". Limited backtrace at point of segmentation fault /lib/x86_64-linux-gnu/libpthread.so.0(+0x12890)[0x7fc8d9e0c890] /lib/x86_64-linux-gnu/libc.so.6(_longjmp+0x10)[0x7fc8d96a9c30] /lib/x86_64-linux-gnu/libpthread.so.0(+0x10f39)[0x7fc8d9e0af39] /var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/x86_64-linux-gnu/omc/libSimulationRuntimeC.so(+0xef87d)[0x7fc8d47fb87d] /var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/x86_64-linux-gnu/omc/libSimulationRuntimeC.so(+0xef586)[0x7fc8d47fb586] /var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/Modelica_3.2.2_cs_Modelica.Fluid.Examples.Tanks.EmptyTanks/temp_Modelica_3_2_2_cs_Modelica_Fluid_Examples_Tanks_EmptyTanks_fmu/model-pipxmhc4/temp/fmu/binaries/linux64/Modelica_3_2_2_cs_Modelica_Fluid_Examples_Tanks_EmptyTanks.so(Modelica_3_2_2_cs_Modelica_Fluid_Examples_Tanks_EmptyTanks_eqFunction_394+0x19c)[0x7fc8d4a6e61e] /var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/Modelica_3.2.2_cs_Modelica.Fluid.Examples.Tanks.EmptyTanks/temp_Modelica_3_2_2_cs_Modelica_Fluid_Examples_Tanks_EmptyTanks_fmu/model-pipxmhc4/temp/fmu/binaries/linux64/Modelica_3_2_2_cs_Modelica_Fluid_Examples_Tanks_EmptyTanks.so(Modelica_3_2_2_cs_Modelica_Fluid_Examples_Tanks_EmptyTanks_functionAlgebraics+0x10c)[0x7fc8d4a81a80] /var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/Modelica_3.2.2_cs_Modelica.Fluid.Examples.Tanks.EmptyTanks/temp_Modelica_3_2_2_cs_Modelica_Fluid_Examples_Tanks_EmptyTanks_fmu/model-pipxmhc4/temp/fmu/binaries/linux64/Modelica_3_2_2_cs_Modelica_Fluid_Examples_Tanks_EmptyTanks.so(fmi2GetBoolean+0x13a)[0x7fc8d4a69d2a] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(_ZN3oms14ComponentFMUCS10getBooleanERKjRb+0x55)[0x5577e382aa05] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(_ZN3oms14ComponentFMUCS13updateSignalsERNS_12ResultWriterE+0x18e)[0x5577e382d64e] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(_ZN3oms6System13updateSignalsERNS_12ResultWriterE+0x70)[0x5577e37c3df0] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(_ZN3oms5Model4emitEdb+0x40)[0x5577e3857640] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(_ZN3oms8SystemWC9stepUntilEdPFvPKcd16oms_status_enu_tE+0x93a)[0x5577e37f478a] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(_ZN3oms5Model8simulateEv+0x54)[0x5577e3858f84] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(oms_simulate+0x51)[0x5577e3798b91]