OMSimulator -r=ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestPipesAndValves.SeriesPipes1_res.mat --tempDir=temp_ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_SeriesPipes1_fmu --startTime=0 --stopTime=5 --timeout=50 --tolerance=1e-06 ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_SeriesPipes1.fmu info: Set temp directory to "/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestPipesAndValves.SeriesPipes1" info: Set working directory to "/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestPipesAndValves.SeriesPipes1" info: New temp directory has been created: "temp_ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_SeriesPipes1_fmu" info: Set temp directory to "/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestPipesAndValves.SeriesPipes1/temp_ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_SeriesPipes1_fmu" info: Set working directory to "/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestPipesAndValves.SeriesPipes1" info: New model "model" with corresponding temp directory "/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestPipesAndValves.SeriesPipes1/temp_ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_SeriesPipes1_fmu/model-2i4jo3fz" info: Result file: ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestPipesAndValves.SeriesPipes1_res.mat (bufferSize=1) error: [fmi2logger] fmu (logStatusError): /var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Media/Water/IF97_Utilities.mo:2897: IF97 medium function tsat called with too low pressure p = -4.47879e+07 Pa <= 611.657 Pa (triple point pressure) error: [fmi2logger] fmu (logFmi2Call): fmi2CompletedIntegratorStep: terminated by an assertion. error: [fmi2logger] fmu (logStatusError): /var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Media/Water/IF97_Utilities.mo:2897: IF97 medium function tsat called with too low pressure p = -4.47879e+07 Pa <= 611.657 Pa (triple point pressure) Limited backtrace at point of segmentation fault /lib/x86_64-linux-gnu/libpthread.so.0(+0x12890)[0x7f15dfefa890] /lib/x86_64-linux-gnu/libc.so.6(_longjmp+0x10)[0x7f15df797c30] /lib/x86_64-linux-gnu/libpthread.so.0(+0x10f39)[0x7f15dfef8f39] /var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestPipesAndValves.SeriesPipes1/temp_ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_SeriesPipes1_fmu/model-2i4jo3fz/temp/fmu/binaries/linux64/ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_SeriesPipes1.so(+0x3c264)[0x7f15daaae264] /var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestPipesAndValves.SeriesPipes1/temp_ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_SeriesPipes1_fmu/model-2i4jo3fz/temp/fmu/binaries/linux64/ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_SeriesPipes1.so(omc_Modelica_Media_Water_IF97__Utilities_BaseIF97_Basic_tsat+0x9e0)[0x7f15daaef031] /var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestPipesAndValves.SeriesPipes1/temp_ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_SeriesPipes1_fmu/model-2i4jo3fz/temp/fmu/binaries/linux64/ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_SeriesPipes1.so(omc_Modelica_Media_Water_IF97__Utilities_BaseIF97_Regions_dewcurve__p+0x50)[0x7f15daade845] /var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestPipesAndValves.SeriesPipes1/temp_ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_SeriesPipes1_fmu/model-2i4jo3fz/temp/fmu/binaries/linux64/ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_SeriesPipes1.so(ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_SeriesPipes1_eqFunction_896+0x25)[0x7f15daac7f61] /var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestPipesAndValves.SeriesPipes1/temp_ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_SeriesPipes1_fmu/model-2i4jo3fz/temp/fmu/binaries/linux64/ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_SeriesPipes1.so(ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_SeriesPipes1_functionODE+0x290)[0x7f15daace1ce] /var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestPipesAndValves.SeriesPipes1/temp_ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_SeriesPipes1_fmu/model-2i4jo3fz/temp/fmu/binaries/linux64/ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_SeriesPipes1.so(fmi2GetBoolean+0x118)[0x7f15daac390f] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(_ZN3oms14ComponentFMUCS10getBooleanERKjRb+0x55)[0x55d4c31f2a05] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(_ZN3oms14ComponentFMUCS13updateSignalsERNS_12ResultWriterE+0x18e)[0x55d4c31f564e] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(_ZN3oms6System13updateSignalsERNS_12ResultWriterE+0x70)[0x55d4c318bdf0] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(_ZN3oms5Model4emitEdb+0x40)[0x55d4c321f640] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(_ZN3oms8SystemWC9stepUntilEdPFvPKcd16oms_status_enu_tE+0x93a)[0x55d4c31bc78a] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(_ZN3oms5Model8simulateEv+0x54)[0x55d4c3220f84]