OMSimulator -r=ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes3_res.mat --tempDir=temp_ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_BranchingPipes3_fmu --startTime=0 --stopTime=5 --timeout=50 --tolerance=1e-06 ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_BranchingPipes3.fmu info: Set temp directory to "/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes3" info: Set working directory to "/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes3" info: New temp directory has been created: "temp_ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_BranchingPipes3_fmu" info: Set temp directory to "/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes3/temp_ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_BranchingPipes3_fmu" info: Set working directory to "/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes3" info: New model "model" with corresponding temp directory "/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes3/temp_ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_BranchingPipes3_fmu/model-xvbmc17g" info: Result file: ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes3_res.mat (bufferSize=1) error: [fmi2logger] fmu (logStatusError): /var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Media/Water/IF97_Utilities.mo:2897: IF97 medium function tsat called with too low pressure p = -3.1768e+06 Pa <= 611.657 Pa (triple point pressure) error: [fmi2logger] fmu (logFmi2Call): fmi2CompletedIntegratorStep: terminated by an assertion. error: [fmi2logger] fmu (logStatusError): /var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Media/Water/IF97_Utilities.mo:2897: IF97 medium function tsat called with too low pressure p = -3.1768e+06 Pa <= 611.657 Pa (triple point pressure) Limited backtrace at point of segmentation fault /lib/x86_64-linux-gnu/libpthread.so.0(+0x12890)[0x7fe6727b3890] /lib/x86_64-linux-gnu/libc.so.6(_longjmp+0x10)[0x7fe672050c30] /lib/x86_64-linux-gnu/libpthread.so.0(+0x10f39)[0x7fe6727b1f39] /var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes3/temp_ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_BranchingPipes3_fmu/model-xvbmc17g/temp/fmu/binaries/linux64/ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_BranchingPipes3.so(+0x3baf4)[0x7fe66d373af4] /var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes3/temp_ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_BranchingPipes3_fmu/model-xvbmc17g/temp/fmu/binaries/linux64/ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_BranchingPipes3.so(omc_Modelica_Media_Water_IF97__Utilities_BaseIF97_Basic_tsat+0x9e0)[0x7fe66d3ae14e] /var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes3/temp_ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_BranchingPipes3_fmu/model-xvbmc17g/temp/fmu/binaries/linux64/ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_BranchingPipes3.so(omc_Modelica_Media_Water_IF97__Utilities_BaseIF97_Regions_dewcurve__p+0x50)[0x7fe66d39d962] /var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes3/temp_ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_BranchingPipes3_fmu/model-xvbmc17g/temp/fmu/binaries/linux64/ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_BranchingPipes3.so(ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_BranchingPipes3_eqFunction_844+0x25)[0x7fe66d38c9af] /var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes3/temp_ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_BranchingPipes3_fmu/model-xvbmc17g/temp/fmu/binaries/linux64/ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_BranchingPipes3.so(ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_BranchingPipes3_functionODE+0x200)[0x7fe66d391764] /var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestPipesAndValves.BranchingPipes3/temp_ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_BranchingPipes3_fmu/model-xvbmc17g/temp/fmu/binaries/linux64/ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestPipesAndValves_BranchingPipes3.so(fmi2GetBoolean+0x118)[0x7fe66d3879c5] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(_ZN3oms14ComponentFMUCS10getBooleanERKjRb+0x55)[0x56178632ca05] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(_ZN3oms14ComponentFMUCS13updateSignalsERNS_12ResultWriterE+0x18e)[0x56178632f64e] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(_ZN3oms6System13updateSignalsERNS_12ResultWriterE+0x70)[0x5617862c5df0] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(_ZN3oms5Model4emitEdb+0x40)[0x561786359640] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(_ZN3oms8SystemWC9stepUntilEdPFvPKcd16oms_status_enu_tE+0x93a)[0x5617862f678a] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(_ZN3oms5Model8simulateEv+0x54)[0x56178635af84]