OMSimulator --tempDir=temp_Buildings_6_0_0_Buildings_Fluid_HeatExchangers_CoolingTowers_Examples_YorkCalc_fmu --startTime=1.5552e+07 --stopTime=1.57248e+07 --timeout=50 --tolerance=1e-06 Buildings_6_0_0_Buildings_Fluid_HeatExchangers_CoolingTowers_Examples_YorkCalc.fmu stdout | info | ... loading "tab1" from "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_6.0.0_Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.YorkCalc/temp_Buildings_6_0_0_Buildings_Fluid_HeatExchangers_CoolingTowers_Examples_YorkCalc_fmu/model-wgei4i1f/temp/0001_fmu/resources/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Resources/weatherdata/USA_CA_San.Francisco.Intl.AP.724940_TMY3.mos" warning: fmu (logStatusWarning): /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352: The following assertion has been violated during initialization at time 0.000000 pum.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. warning: fmu (logStatusWarning): /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/HeatExchangers/CoolingTowers/YorkCalc.mo:70: The following assertion has been violated at time 0.000000 tow.TAppFreCon >= 0.0 assert | warning | Variable violating min constraint: 0.0 <= tow.TAppFreCon, has value: -423.471 warning: fmu (logStatusWarning): /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Utilities/Psychrometrics/TWetBul_TDryBulPhi.mo:40: The following assertion has been violated at time 0.000000 weaDat.tWetBul_TDryBulXi.XiSat >= 0.0 and weaDat.tWetBul_TDryBulXi.XiSat <= 1.0 assert | warning | Variable violating min/max constraint: 0.0 <= weaDat.tWetBul_TDryBulXi.XiSat <= 1.0, has value: -1.64772 warning: fmu (logStatusWarning): /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Utilities/Psychrometrics/TWetBul_TDryBulPhi.mo:41: The following assertion has been violated at time 0.000000 weaDat.tWetBul_TDryBulXi.XiSatRefIn >= 0.0 and weaDat.tWetBul_TDryBulXi.XiSatRefIn <= 1.0 assert | warning | Variable violating min/max constraint: 0.0 <= weaDat.tWetBul_TDryBulXi.XiSatRefIn <= 1.0, has value: -0.61881 warning: fmu (logStatusWarning): /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Utilities/Psychrometrics/TWetBul_TDryBulPhi.mo:40: The following assertion has been violated at time 0.000000 wetBulTem.XiSat >= 0.0 and wetBulTem.XiSat <= 1.0 assert | warning | Variable violating min/max constraint: 0.0 <= wetBulTem.XiSat <= 1.0, has value: -1.64772 warning: fmu (logStatusWarning): /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Utilities/Psychrometrics/TWetBul_TDryBulPhi.mo:41: The following assertion has been violated at time 0.000000 wetBulTem.XiSatRefIn >= 0.0 and wetBulTem.XiSatRefIn <= 1.0 assert | warning | Variable violating min/max constraint: 0.0 <= wetBulTem.XiSatRefIn <= 1.0, has value: -0.61881 info: maximum step size for 'model.root': -1555199.900000 [CVODE ERROR] CVodeSetMaxStep hmax < 0 illegal. error: [initialize] SUNDIALS_ERROR: CVodeSetMaxStep() failed with flag = -22 info: Result file: model_res.mat (bufferSize=10) info: Variable model.root.fmu.weaDat.datRea.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.fmu.weaDat.datRea.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.fmu.weaDat.datRea1.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.fmu.weaDat.datRea1.tableName will not be stored in the result file, because the signal type is not supported [CVODE WARNING] CVode Internal t = 1.55537e+07 and h = 7.05967e-10 are such that t + h = t on the next step. The solver will continue anyway. [CVODE WARNING] CVode Internal t = 1.55537e+07 and h = 7.05967e-10 are such that t + h = t on the next step. The solver will continue anyway. [CVODE WARNING] CVode Internal t = 1.55537e+07 and h = 7.05967e-10 are such that t + h = t on the next step. The solver will continue anyway. [CVODE WARNING] CVode Internal t = 1.55537e+07 and h = 7.05967e-10 are such that t + h = t on the next step. The solver will continue anyway. [CVODE WARNING] CVode Internal t = 1.55537e+07 and h = 7.05967e-10 are such that t + h = t on the next step. The solver will continue anyway. [CVODE WARNING] CVode Internal t = 1.55537e+07 and h = 5.2316e-10 are such that t + h = t on the next step. The solver will continue anyway. [CVODE WARNING] CVode Internal t = 1.55537e+07 and h = 5.2316e-10 are such that t + h = t on the next step. The solver will continue anyway. [CVODE WARNING] CVode Internal t = 1.55537e+07 and h = 5.2316e-10 are such that t + h = t on the next step. The solver will continue anyway. [CVODE WARNING] CVode Internal t = 1.55537e+07 and h = 5.2316e-10 are such that t + h = t on the next step. The solver will continue anyway. [CVODE WARNING] CVode Internal t = 1.55537e+07 and h = 5.2316e-10 are such that t + h = t on the next step. The solver will continue anyway. [CVODE WARNING] CVode The above warning has been issued mxhnil times and will not be issued again for this problem. [CVODE ERROR] CVode At t = 1.55537e+07 and h = 1e-12, the error test failed repeatedly or with |h| = hmin. error: [doStep] SUNDIALS_ERROR: CVode() failed with flag = -3 warning: fmu (logStatusWarning): /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Media/Water.mo:59: The following assertion has been violated at time 15553745.454545 tow.vol.dynBal.medium.T <= 403.15 assert | error | | | | | In Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.YorkCalc.tow.vol.dynBal.medium: Temperature T exceeded its maximum allowed value of 130 degC (403.15 Kelvin) | | | | as required from medium model "SimpleLiquidWater". error: [fmi2logger] fmu (logFmi2Call): fmi2CompletedIntegratorStep: terminated by an assertion. error: [doStep] fmi2_import_completed_integrator_step failed for FMU "model.root.fmu" warning: fmu (logStatusWarning): /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Media/Water.mo:59: The following assertion has been violated at time 15553745.454545 tow.vol.dynBal.medium.T <= 403.15 assert | error | | | | | In Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.YorkCalc.tow.vol.dynBal.medium: Temperature T exceeded its maximum allowed value of 130 degC (403.15 Kelvin) | | | | as required from medium model "SimpleLiquidWater". error: [fmi2logger] fmu (logFmi2Call): fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable switch1.u2 info: Final Statistics for 'model.root': NumSteps = 443 NumRhsEvals = 720 NumLinSolvSetups = 79 NumNonlinSolvIters = 719 NumNonlinSolvConvFails = 0 NumErrTestFails = 71 info: 8 warnings info: 6 errors