Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermofluidStream_dev_ThermofluidStream.Processes.Tests.CentrifugalPumpCharacteristics.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.00179/0.00179, allocations: 78.31 kB / 19.01 MB, free: 2.566 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.002115/0.002115, allocations: 160.3 kB / 22.25 MB, free: 4.855 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.388/1.388, allocations: 177.2 MB / 202.6 MB, free: 8.039 MB / 190.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo): time 0.6995/0.6995, allocations: 79.61 MB / 338.6 MB, free: 5.293 MB / 318.1 MB " [Timeout remaining time 179] Using package ThermofluidStream with version 1.2.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(ThermofluidStream.Processes.Tests.CentrifugalPumpCharacteristics,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Processes_Tests_CentrifugalPumpCharacteristics",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermofluidStream.Processes.Tests.CentrifugalPumpCharacteristics,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Processes_Tests_CentrifugalPumpCharacteristics",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: ThermofluidStream requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: ThermofluidStream requested package Complex of version 4.0.0. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002774/0.002774, allocations: 87.86 kB / 0.4911 GB, free: 10.34 MB / 478.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3737/0.3764, allocations: 74.57 MB / 0.564 GB, free: 45.67 MB / 0.5138 GB Notification: Performance of NFInst.instantiate(ThermofluidStream.Processes.Tests.CentrifugalPumpCharacteristics): time 0.04451/0.4209, allocations: 49.42 MB / 0.6122 GB, free: 12.52 MB / 0.5138 GB Notification: Performance of NFInst.instExpressions: time 0.02607/0.447, allocations: 23.8 MB / 0.6355 GB, free: 10.1 MB / 0.5294 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.001817/0.4488, allocations: 53.94 kB / 0.6355 GB, free: 10.07 MB / 0.5294 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Processes/Internal/CentrifugalPump/Measurements/GenericPump.mo:9:41-9:59:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Processes/Internal/CentrifugalPump/Measurements/GenericPump.mo:9:3-10:50:writable] Error: Non-array modification '\"m3/h\"' for array component 'displayUnit', possibly due to missing 'each'. Notification: Performance of FrontEnd: time 0.001261/0.4501, allocations: 245.1 kB / 0.6358 GB, free: 9.887 MB / 0.5294 GB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 3.6932769150007516] Failed to read output from testmodel.py, exit status != 0: 0.4573769089765847 0.48202896900000003 -1.0 Calling exit ...