Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermofluidStream_dev_ThermofluidStream.Processes.Tests.CentrifugalPump.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001904/0.001904, allocations: 103.6 kB / 18.95 MB, free: 2.66 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.002816/0.002816, allocations: 218.5 kB / 22.24 MB, free: 5.258 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.993/1.993, allocations: 230.6 MB / 256 MB, free: 7.816 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo): time 1.317/1.317, allocations: 100.3 MB / 412.8 MB, free: 3.418 MB / 318.1 MB " [Timeout remaining time 178] Using package ThermofluidStream with version 1.2.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(ThermofluidStream.Processes.Tests.CentrifugalPump,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Processes_Tests_CentrifugalPump",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermofluidStream.Processes.Tests.CentrifugalPump,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Processes_Tests_CentrifugalPump",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: ThermofluidStream requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: ThermofluidStream requested package Complex of version 4.0.0. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.007383/0.007383, allocations: 82.89 kB / 0.5632 GB, free: 35.72 MB / 446.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2996/0.307, allocations: 74.48 MB / 0.636 GB, free: 7.254 MB / 478.1 MB Notification: Performance of NFInst.instantiate(ThermofluidStream.Processes.Tests.CentrifugalPump): time 1.176/1.483, allocations: 181.2 MB / 0.8129 GB, free: 2.355 MB / 0.5763 GB Notification: Performance of NFInst.instExpressions: time 0.04719/1.53, allocations: 21.03 MB / 0.8335 GB, free: 6.266 MB / 0.5919 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.006164/1.536, allocations: 95.72 kB / 0.8335 GB, free: 6.266 MB / 0.5919 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Processes/Internal/CentrifugalPump/Measurements/GenericPump.mo:9:41-9:59:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Processes/Internal/CentrifugalPump/Measurements/GenericPump.mo:9:3-10:50:writable] Error: Non-array modification '\"m3/h\"' for array component 'displayUnit', possibly due to missing 'each'. Notification: Performance of FrontEnd: time 0.004562/1.541, allocations: 0.6732 MB / 0.8342 GB, free: 6.141 MB / 0.5919 GB " [Timeout remaining time 658] [Calling sys.exit(0), Time elapsed: 6.778190527984407] Failed to read output from testmodel.py, exit status != 0: 1.5557536160049494 1.571388439 -1.0 Calling exit ...