Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermofluidStream_ThermofluidStream.Boundaries.Tests.TankOverfilling.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.0008802/0.0008802, allocations: 80.44 kB / 19.17 MB, free: 0.7305 MB / 13.93 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001498/0.001498, allocations: 169.9 kB / 22.45 MB, free: 2.094 MB / 18.57 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 0.8586/0.8586, allocations: 177.2 MB / 202.8 MB, free: 5.762 MB / 186.7 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.3.0/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.3.0/package.mo): time 0.4839/0.4839, allocations: 80.18 MB / 339.4 MB, free: 7.543 MB / 314.7 MB " [Timeout remaining time 179] Using package ThermofluidStream with version 1.3.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.3.0/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(ThermofluidStream.Boundaries.Tests.TankOverfilling,fileNamePrefix="ThermofluidStream_ThermofluidStream_Boundaries_Tests_TankOverfilling",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermofluidStream.Boundaries.Tests.TankOverfilling,fileNamePrefix="ThermofluidStream_ThermofluidStream_Boundaries_Tests_TankOverfilling",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 1.793e-06/1.793e-06, allocations: 0 / 0.4924 GB, free: 6.66 MB / 410.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 2.43e-05/2.609e-05, allocations: 6.219 kB / 0.4925 GB, free: 6.652 MB / 410.7 MB Notification: Performance of NFInst.instantiate(ThermofluidStream.Boundaries.Tests.TankOverfilling): time 0.4102/0.4102, allocations: 229.1 MB / 0.7162 GB, free: 2.746 MB / 0.5417 GB Notification: Performance of NFInst.instExpressions: time 0.006074/0.4163, allocations: 4.802 MB / 0.7209 GB, free: 2.449 MB / 0.5417 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.0007419/0.417, allocations: 44.78 kB / 0.7209 GB, free: 2.449 MB / 0.5417 GB Notification: Performance of NFTyping.typeComponents: time 0.001325/0.4184, allocations: 0.6028 MB / 0.7215 GB, free: 2.359 MB / 0.5417 GB Notification: Performance of NFTyping.typeBindings: time 0.005631/0.424, allocations: 3.089 MB / 0.7245 GB, free: 1.773 MB / 0.5417 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.3.0/Boundaries/AccelerationBoundary.mo:21:3-21:19:writable] Error: acceleration.a[1] is not a valid connector. Notification: Performance of FrontEnd: time 0.0006466/0.4246, allocations: 360.9 kB / 0.7249 GB, free: 1.688 MB / 0.5417 GB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 2.5640702596865594] Failed to read output from testmodel.py, exit status != 0: 0.4295596503652632 0.43888201600000004 -1.0 Calling exit ...