(cd run_OMSimulator && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_ThermoPower_4_0_0-dev_ThermoPower_Examples_BraytonCycle_OpenLoopSimulator_fmu --startTime=0 --stopTime=1000 --stepSize=0.4 --mode=me --timeout=240 --tolerance=1e-06 ../ThermoPower_4_0_0-dev_ThermoPower_Examples_BraytonCycle_OpenLoopSimulator.fmu) info: *** FMU Simulation Info *** - model : ThermoPower.Examples.BraytonCycle.OpenLoopSimulator (model exchange) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 1000.000000 - tolerance : 1e-06 - stepSize : 0.4 info: maximum step size for 'OpenLoopSimulator.root': 0.400000 info: Result file: ThermoPower_4_0_0-dev_ThermoPower_Examples_BraytonCycle_OpenLoopSimulator_res.mat (bufferSize=10) info: Parameter OpenLoopSimulator.plant.compressor.Eta.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter OpenLoopSimulator.plant.compressor.Eta.fileName will not be stored in the result file, because the signal type is not supported info: Parameter OpenLoopSimulator.plant.compressor.Eta.tableName will not be stored in the result file, because the signal type is not supported info: Parameter OpenLoopSimulator.plant.compressor.Phic.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter OpenLoopSimulator.plant.compressor.Phic.fileName will not be stored in the result file, because the signal type is not supported info: Parameter OpenLoopSimulator.plant.compressor.Phic.tableName will not be stored in the result file, because the signal type is not supported info: Parameter OpenLoopSimulator.plant.compressor.PressRatio.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter OpenLoopSimulator.plant.compressor.PressRatio.fileName will not be stored in the result file, because the signal type is not supported info: Parameter OpenLoopSimulator.plant.compressor.PressRatio.tableName will not be stored in the result file, because the signal type is not supported info: Parameter OpenLoopSimulator.plant.compressor.fileName will not be stored in the result file, because the signal type is not supported info: Parameter OpenLoopSimulator.plant.turbine.Eta.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter OpenLoopSimulator.plant.turbine.Eta.fileName will not be stored in the result file, because the signal type is not supported info: Parameter OpenLoopSimulator.plant.turbine.Eta.tableName will not be stored in the result file, because the signal type is not supported info: Parameter OpenLoopSimulator.plant.turbine.Phic.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter OpenLoopSimulator.plant.turbine.Phic.fileName will not be stored in the result file, because the signal type is not supported info: Parameter OpenLoopSimulator.plant.turbine.Phic.tableName will not be stored in the result file, because the signal type is not supported info: Parameter OpenLoopSimulator.plant.turbine.fileName will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'OpenLoopSimulator.root': NumSteps = 1318 NumRhsEvals = 1358 NumLinSolvSetups = 87 NumNonlinSolvIters = 1357 NumNonlinSolvConvFails = 0 NumErrTestFails = 8