ThermoPower test using OpenModelica

Total Frontend Backend SimCode Templates Compilation Simulation Verification
108 101 101 101 99 99 78 0

Test started: 2024-12-17 03:48:40
Total time taken: 0:48:50
System info: AMD Ryzen 9 5950X 16-Core Processor, 63 GB RAM, Ubuntu 22.04.3 LTS

OpenModelica Version: OMCompiler v1.25.0-dev.262+gb916c673da

FMI tool: b"warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input\nOMSimulator v3.0.0.post53-g193355b-linux-debug\ninfo: 1 warnings\ninfo: 0 errors"

FMI version: 2.0

OpenModelicaLibraryTesting Changes
CommitDateAuthorSummary
4c1c1162024-12-05 12:04:10 +0100Francesco CasellaIncreased simulation time allowance for Buildings_latest (#187)

Tested Library: ThermoPower 3.1 warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input OMSimulator v3.0.0.post53-g193355b-linux-debug info: 1 warnings info: 0 errors

{
 "path": "ThermoPower",
 "sha": "e2b011ac7fd90f9cf5771f29f1aefa160550b6ee",
 "support": "experimental",
 "uses": {
  "Modelica": "3.2.3"
 },
 "version": "3.1.0-master",
 "zipfile": "https://github.com/casella/ThermoPower/archive/e2b011ac7fd90f9cf5771f29f1aefa160550b6ee.zip"
}

BuildModel time limit: 660s
Simulation time limit: 50s
Default tolerance: 1e-06
Default number of intervals: 2500
Optimization level: -Os -march=native

Flags:
setCommandLineOptions("-d=nogen");
setCommandLineOptions("-d=initialization");
setCommandLineOptions("-d=backenddaeinfo");
setCommandLineOptions("-d=discreteinfo");
setCommandLineOptions("-d=stateselection");
setCommandLineOptions("-d=execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");
Config:
{
 "library": "ThermoPower",
 "optlevel": "-Os -march=native"
}

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

ModelVerifiedSimulateTotal buildModelParsingFrontendBackendSimCodeTemplatesCompileTotal Execution
ThermoPower.Examples.BraytonCycle.ClosedLoopSimulator (sim) 1.0120.222.151.050.230.090.1818.6624.01
ThermoPower.Examples.BraytonCycle.OpenLoopSimulator (sim) 0.9520.012.071.040.200.270.1818.3123.68
ThermoPower.Examples.CISE.Simulators.CISESim2States120501 (sim) 1.4527.672.280.602.960.260.6123.2432.06
ThermoPower.Examples.CISE.Simulators.CISESim120501 (sim) 4.1446.582.061.004.700.810.9539.1253.38
ThermoPower.Examples.CISE.Simulators.CISESim180503 (sim) 1.0845.831.990.984.400.851.2338.3849.49
ThermoPower.Examples.CISE.Simulators.CISESim180504 (sim) 1.1046.772.181.134.410.821.2339.1850.68
ThermoPower.Examples.HRB.Simulators.ClosedLoopDigitalSimulator (sim) 0.5631.752.021.061.790.240.6827.9834.93
ThermoPower.Examples.HRB.Simulators.ClosedLoopDigitalSimulatorSimplified (sim) 1.0325.682.061.141.150.180.5122.6929.41
ThermoPower.Examples.HRB.Simulators.ClosedLoopSimulator (sim) 0.5832.132.141.061.760.220.6628.4235.47
ThermoPower.Examples.HRB.Simulators.OpenLoopSimulator (sim) 2.0430.142.151.261.680.260.6726.2735.00
ThermoPower.Examples.HRB.Simulators.OpenLoopSimulatorHtc 0.003.812.151.071.800.230.710.006.70
ThermoPower.Examples.HRB.Simulators.OpenLoopSimulatorSS (sim) 0.5431.832.191.131.890.210.6727.9435.19
ThermoPower.Examples.HRB.Simulators.OpenLoopSimulatorSimplified (sim) 0.9125.442.141.121.020.160.5422.5929.11
ThermoPower.Examples.HRB.Simulators.TestPI (sim) 0.098.482.070.130.020.210.038.0911.25
ThermoPower.Examples.RankineCycle.Simulators.ClosedLoop (sim) 2.0847.822.131.305.190.741.2639.3452.66
ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE 0.000.412.120.410.000.000.000.003.20
ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE_breaker 0.000.442.260.440.000.000.000.003.42
ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE_com 0.000.442.290.440.000.000.000.003.43
ThermoPower.PowerPlants.Simulators.CCPP_Sim3 0.002.212.272.210.000.000.000.005.21
ThermoPower.PowerPlants.Simulators.SteamPlant_Sim1 0.003.022.273.020.000.000.000.006.08
ThermoPower.PowerPlants.Simulators.SteamPlant_Sim1_dp 0.002.102.212.100.000.000.000.005.03
ThermoPower.PowerPlants.Simulators.SteamPlant_Sim2 0.002.862.182.860.000.000.000.005.82
ThermoPower.PowerPlants.SteamTurbineGroup.Tests.TestST3LRh_base (sim) 0.2517.362.110.580.400.030.1016.2620.39
ThermoPower.PowerPlants.SteamTurbineGroup.Tests.TestST3LRh_bypass (sim) 0.7421.282.061.080.270.050.1719.7124.65
ThermoPower.PowerPlants.SteamTurbineGroup.Tests.TestST3LRh_valve (sim) 1.0218.942.080.600.470.030.1117.7322.68
ThermoPower.PowerPlants.SteamTurbineGroup.Tests.TestSTG_cc (sim) 3.6221.512.090.670.470.040.4119.9327.87
ThermoPower.PowerPlants.SteamTurbineGroup.Tests.TestTurbineHPefficiency 0.000.812.140.490.180.020.110.0012.47
ThermoPower.Test.DistributedParameterComponents.CheckFlow1DFV2phMassBalance (sim) 0.5212.792.000.420.340.050.2811.7015.96
ThermoPower.Test.DistributedParameterComponents.TestConstantHeatTransferTwoGrid_Fcoarse (sim) 0.159.822.170.370.060.020.069.3112.78
ThermoPower.Test.DistributedParameterComponents.TestConstantHeatTransferTwoGrid_Wcoarse (sim) 0.2610.542.100.380.070.020.0610.0113.49
ThermoPower.Test.DistributedParameterComponents.TestFlow1D2phChen (sim) 3.4128.842.100.482.560.560.6024.6434.92
ThermoPower.Test.DistributedParameterComponents.TestFlow1D2phChen_hf (sim) 3.5530.832.140.474.081.310.5724.4037.10
ThermoPower.Test.DistributedParameterComponents.TestFlow1D2phDB (sim) 0.2028.262.050.482.530.340.5524.3631.10
ThermoPower.Test.DistributedParameterComponents.TestFlow1D2phDB_hf (sim) 3.1730.192.370.453.621.480.5624.0936.38
ThermoPower.Test.DistributedParameterComponents.TestFlow1Dfem2ph (sim) 4.9952.282.110.517.322.241.0941.1360.01
ThermoPower.Test.DistributedParameterComponents.TestFlowDependentHeatTransferCoefficient2ph (sim) 0.5712.862.120.380.370.100.3111.7016.18
ThermoPower.Test.DistributedParameterComponents.TestGasFlow1DFV_A (sim) 0.2218.092.160.650.470.080.1016.7821.09
ThermoPower.Test.DistributedParameterComponents.TestGasFlow1DFV_B (sim) 0.2918.862.160.630.680.210.3516.9921.96
ThermoPower.Test.DistributedParameterComponents.TestGasFlow1DFV_C (sim) 0.3319.532.240.620.710.460.1417.6022.70
ThermoPower.Test.DistributedParameterComponents.TestHeatTransfer2phDB (sim) 0.6213.362.190.400.390.100.3212.1716.77
ThermoPower.Test.DistributedParameterComponents.TestRefrigerantEvaporator (sim) 50.4339.782.131.123.431.160.7933.2793.02
ThermoPower.Test.DistributedParameterComponents.TestWalls (sim) 0.108.972.100.500.010.010.038.4111.76
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_A (sim) 29.2830.172.100.471.460.140.5027.5962.17
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_B (sim) 20.1730.822.150.491.550.140.5228.1153.75
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_C (sim) 17.7630.342.200.491.440.140.5327.7450.95
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_D (sim) 50.1029.862.140.491.450.150.5227.2682.74
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_E (sim) 50.1253.612.180.623.110.580.7448.55106.51
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_F (sim) 50.27125.822.180.655.010.931.43117.79178.92
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_G (sim) 2.7220.482.190.490.790.080.4018.7326.08
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_J (sim) 2.5727.112.270.531.180.410.4724.5332.60
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_K (sim) 1.4727.362.200.571.490.170.4824.6631.64
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV2ph (sim) 0.3644.352.370.635.540.941.4035.8447.74
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV2ph_A (sim) 2.2326.542.330.542.270.330.5122.9031.75
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV2ph_B (sim) 2.1826.272.170.472.210.310.5122.7731.25
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV2ph_C (sim) 10.0143.882.030.515.351.011.2435.7856.54
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV2ph_D (sim) 2.1826.752.100.432.220.320.5123.2731.66
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_A (sim) 2.3022.872.110.480.820.090.4821.0127.88
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_A_Fast (sim) 0.3419.142.130.540.300.290.1417.8722.23
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_AdaptiveAverageTemp (sim) 0.5517.732.060.430.300.040.3216.6420.93
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_B (sim) 1.0119.672.130.490.650.050.4118.0723.45
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_D (sim) 0.6216.622.110.470.250.040.3615.4919.93
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_DB (sim) 1.2821.752.140.480.820.080.4419.9325.79
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_E (sim) 5.3636.932.120.531.860.210.9233.4145.05
ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_F (sim) 5.5141.272.060.562.060.501.1437.0149.46
ThermoPower.Test.ElectricalComponents.TestElectrical1 (sim) 0.088.582.080.120.010.010.228.2111.37
ThermoPower.Test.ElectricalComponents.TestElectrical2 (sim) 0.088.492.160.120.020.010.228.1211.32
ThermoPower.Test.ElectricalComponents.TestElectrical3 (sim) 0.128.452.170.120.020.200.038.0911.37
ThermoPower.Test.ElectricalComponents.TestElectrical4 (sim) 0.118.512.190.130.020.210.038.1311.45
ThermoPower.Test.ElectricalComponents.TestElectrical5 (sim) 0.1310.602.150.130.220.010.0310.2113.52
ThermoPower.Test.ElectricalComponents.TestElectrical6 (sim) 0.1312.742.110.160.210.010.0412.3315.55
ThermoPower.Test.ElectricalComponents.TestElectrical7 (sim) 0.189.172.100.130.210.010.038.7912.07
ThermoPower.Test.GasComponents.TestCC (sim) 0.5414.912.080.600.290.030.0713.9318.16
ThermoPower.Test.GasComponents.TestCompressorConstSpeed (sim) 0.1814.392.010.540.030.020.2713.5317.18
ThermoPower.Test.GasComponents.TestCompressorInertia (sim) 0.2014.522.060.600.030.030.2913.5717.42
ThermoPower.Test.GasComponents.TestFanMech (sim) 0.7413.202.080.530.060.020.0512.5416.64
ThermoPower.Test.GasComponents.TestGT (sim) 0.3116.542.070.560.050.250.0815.6119.51
ThermoPower.Test.GasComponents.TestGT_ISO (sim) 0.2914.642.080.580.060.230.0713.7017.59
ThermoPower.Test.GasComponents.TestGasMixer (sim) 0.2714.302.020.550.280.030.0713.3817.16
ThermoPower.Test.GasComponents.TestGasTurbine (sim) 0.1613.802.100.590.250.020.0612.8916.67
ThermoPower.Test.GasComponents.TestGasTurbineStodola (sim) 0.1613.202.100.560.030.020.0512.5416.07
ThermoPower.Test.GasComponents.TestGasValve (sim) 0.1517.412.050.990.150.050.1316.0920.19
ThermoPower.Test.GasComponents.TestGasValveOpPoint (sim) 0.1316.222.090.620.380.030.0815.1219.09
ThermoPower.Test.GasComponents.TestTurboJetConstSpeed (sim) 0.8519.482.030.980.140.070.1618.1322.97
ThermoPower.Test.GasComponents.TestTurboJetInertia (sim) 0.8819.412.070.950.160.070.1818.0522.95
ThermoPower.Test.WaterComponents.TestAccumulator (sim) 0.1914.792.040.430.100.020.0814.1617.65
ThermoPower.Test.WaterComponents.TestBarometricCondenser (sim) 0.1214.912.190.470.110.020.1014.2017.84
ThermoPower.Test.WaterComponents.TestCoeffValve (sim) 0.1212.112.070.480.100.020.0911.4214.90
ThermoPower.Test.WaterComponents.TestCoolingTowerClosed (sim) 16.9422.202.130.610.670.310.1820.4241.89
ThermoPower.Test.WaterComponents.TestCoolingTowerPacking (sim) 2.7720.472.110.620.440.040.1319.2425.97
ThermoPower.Test.WaterComponents.TestCoolingTowerStatic (sim) 3.9419.812.170.630.460.040.1218.5726.52
ThermoPower.Test.WaterComponents.TestExpansionTankIdeal (sim) 0.4916.312.110.440.240.030.3315.2719.50
ThermoPower.Test.WaterComponents.TestJoin (sim) 0.4611.742.160.580.110.020.0910.9414.97
ThermoPower.Test.WaterComponents.TestJoinRev (sim) 0.3812.132.260.560.140.030.3111.0915.41
ThermoPower.Test.WaterComponents.TestMixer (sim) 0.3215.592.270.530.140.030.1114.7818.80
ThermoPower.Test.WaterComponents.TestMixerSlowFast (sim) 0.3714.962.170.480.140.020.0914.2318.14
ThermoPower.Test.WaterComponents.TestMixerSlowFastSteam (sim) 0.3914.942.200.490.130.020.0914.2018.17
ThermoPower.Test.WaterComponents.TestST1 (sim) 0.3216.312.010.440.170.020.1115.5819.25
ThermoPower.Test.WaterComponents.TestST2 (sim) 0.3214.062.140.480.170.020.1313.2617.16
ThermoPower.Test.WaterComponents.TestSources (sim) 0.1410.132.330.540.030.020.089.4713.23
ThermoPower.Test.WaterComponents.TestSplitRev (sim) 0.3512.122.150.520.130.030.3111.1315.28
ThermoPower.Test.WaterComponents.TestTurbineStodolaPartialArc (sim) 0.1012.102.110.450.160.020.1011.3714.94
ThermoPower.Test.WaterComponents.TestValveChoked (sim) 0.1010.962.060.430.100.020.0810.3313.70
ThermoPower.Test.WaterComponents.TestValves (sim) 1.9515.962.210.520.140.030.1115.1720.72
ThermoPower.Test.WaterComponents.ValveZeroFlow (sim) 0.1814.962.040.430.110.020.0814.3317.80
ThermoPower.Test.WaterComponents.ValveZeroFlow2 (sim) 0.3514.792.090.510.110.020.1014.0517.86
ThermoPower.Test.WaterComponents.WaterPump (sim) 0.5314.042.230.450.110.020.0813.3717.41
ThermoPower.Test.WaterComponents.WaterPumpMech (sim) 0.5214.542.070.460.110.020.0913.8617.74