/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_Physiolibrary_Physiolibrary_Fluid_Examples_CapillaryMembrane_fmu --startTime=0 --stopTime=1 --stepSize=0.0004 --timeout=50 --tolerance=1e-08 Physiolibrary_Physiolibrary_Fluid_Examples_CapillaryMembrane.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Physiolibrary_Physiolibrary.Fluid.Examples.CapillaryMembrane" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Physiolibrary_Physiolibrary.Fluid.Examples.CapillaryMembrane" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Physiolibrary_Physiolibrary.Fluid.Examples.CapillaryMembrane/model-voxwize1" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Physiolibrary_Physiolibrary.Fluid.Examples.CapillaryMembrane" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Physiolibrary_Physiolibrary_Fluid_Examples_CapillaryMembrane.fmu - startTime: 0.000000 - stopTime: 1.000000 - tolerance: 0.000000 - stepSize: 0.000400 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Physiolibrary 3.0.0/Fluid.mo:786:7-786:76:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((Artys.massOffset >= 0.0)) --> "Variable violating min constraint: 0.0 <= Artys.massOffset, has value: -2.49212e-08" error: [fmi2logger] [fmi2Error] Physiolibrary_Physiolibrary_Fluid_Examples_CapillaryMembrane/logStatusError: Model error: Argument of log(pO2CO / 7000.0) was -3.02865 should be > 0 error: [fmi2logger] [fmi2Error] Physiolibrary_Physiolibrary_Fluid_Examples_CapillaryMembrane/logFmi2Call: fmi2ExitInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.Physiolibrary_Physiolibrary_Fluid_Examples_CapillaryMembrane" error: [initialize] Initialization of system "model.root" failed error: [SimulateSingleFMU] oms_initialize failed info: 2 warnings info: 5 errors