OMSimulator -r=Modelica_3.2.3_cpp_Modelica.Fluid.Examples.AST_BatchPlant.Test.TanksWithEmptyingPipe1_res.mat --tempDir=temp_Modelica_3_2_3_cpp_Modelica_Fluid_Examples_AST_BatchPlant_Test_TanksWithEmptyingPipe1_fmu --startTime=0 --stopTime=120 --timeout=50 --tolerance=1e-06 Modelica_3_2_3_cpp_Modelica_Fluid_Examples_AST_BatchPlant_Test_TanksWithEmptyingPipe1.fmu info: maximum step size for 'model.root': 0.001000 info: Result file: Modelica_3.2.3_cpp_Modelica.Fluid.Examples.AST_BatchPlant.Test.TanksWithEmptyingPipe1_res.mat (bufferSize=1) error: [fmi2logger] Modelica_3_2_3_cpp_Modelica_Fluid_Examples_AST_BatchPlant_Test_TanksWithEmptyingPipe1 (logStatusError): Number of event iteration steps exceeded at time: 30.448000 error: [doEventIteration] fmi2_import_new_discrete_states failed for FMU "model.root.Modelica_3_2_3_cpp_Modelica_Fluid_Examples_AST_BatchPlant_Test_TanksWithEmptyingPipe1" error: [fmi2logger] Modelica_3_2_3_cpp_Modelica_Fluid_Examples_AST_BatchPlant_Test_TanksWithEmptyingPipe1 (logStatusError): Nonlinear solver 454 stopped at time error: [updateSignals] failed to fetch variable tank2.use_T_start error: [fmi2logger] Modelica_3_2_3_cpp_Modelica_Fluid_Examples_AST_BatchPlant_Test_TanksWithEmptyingPipe1 (logStatusError): Nonlinear solver 454 stopped at time error: [doStep] fmi2_import_get_event_indicators failed for FMU "model.root.Modelica_3_2_3_cpp_Modelica_Fluid_Examples_AST_BatchPlant_Test_TanksWithEmptyingPipe1" error: [fmi2logger] Modelica_3_2_3_cpp_Modelica_Fluid_Examples_AST_BatchPlant_Test_TanksWithEmptyingPipe1 (logStatusError): Nonlinear solver 454 stopped at time error: [doEventIteration] fmi2_import_new_discrete_states failed for FMU "model.root.Modelica_3_2_3_cpp_Modelica_Fluid_Examples_AST_BatchPlant_Test_TanksWithEmptyingPipe1" error: [fmi2logger] Modelica_3_2_3_cpp_Modelica_Fluid_Examples_AST_BatchPlant_Test_TanksWithEmptyingPipe1 (logStatusError): Nonlinear solver 454 stopped at time error: [getDerivatives] fmi2_import_get_derivatives failed for FMU "model.root.Modelica_3_2_3_cpp_Modelica_Fluid_Examples_AST_BatchPlant_Test_TanksWithEmptyingPipe1" error: [fmi2logger] Modelica_3_2_3_cpp_Modelica_Fluid_Examples_AST_BatchPlant_Test_TanksWithEmptyingPipe1 (logStatusError): Nonlinear solver 454 stopped at time error: [updateSignals] failed to fetch variable tank2.use_T_start info: Final Statistics for 'model.root': NumSteps = 0 NumRhsEvals = 0 NumLinSolvSetups = 0 NumNonlinSolvIters = 1904 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 0 warnings info: 12 errors