/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=ModelicaTest_4.1.0_ModelicaTest.Fluid.TestComponents.Pipes.DynamicPipesAndFittings_res.mat --tempDir=temp_ModelicaTest_4_1_0_ModelicaTest_Fluid_TestComponents_Pipes_DynamicPipesAndFittings_fmu --startTime=0 --stopTime=20 --stepSize=0.0039968 --timeout=50 --tolerance=1e-06 ModelicaTest_4_1_0_ModelicaTest_Fluid_TestComponents_Pipes_DynamicPipesAndFittings.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ModelicaTest_4.1.0_ModelicaTest.Fluid.TestComponents.Pipes.DynamicPipesAndFittings" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ModelicaTest_4.1.0_ModelicaTest.Fluid.TestComponents.Pipes.DynamicPipesAndFittings" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ModelicaTest_4.1.0_ModelicaTest.Fluid.TestComponents.Pipes.DynamicPipesAndFittings/model-vsg2fe4w" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ModelicaTest_4.1.0_ModelicaTest.Fluid.TestComponents.Pipes.DynamicPipesAndFittings" info: *** FMU Simulation Info *** - model: model (model exchange) - path: ModelicaTest_4_1_0_ModelicaTest_Fluid_TestComponents_Pipes_DynamicPipesAndFittings.fmu - startTime: 0.000000 - stopTime: 20.000000 - tolerance: 0.000001 - stepSize: 0.003997 error: [fmi2logger] [fmi2Error] ModelicaTest_4_1_0_ModelicaTest_Fluid_TestComponents_Pipes_DynamicPipesAndFittings/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Media/Water/IF97_Utilities.mo:6695: Error in region computation of IF97 steam tables(p = 100000, h = 0) error: [fmi2logger] [fmi2Error] ModelicaTest_4_1_0_ModelicaTest_Fluid_TestComponents_Pipes_DynamicPipesAndFittings/logFmi2Call: fmi2ExitInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.ModelicaTest_4_1_0_ModelicaTest_Fluid_TestComponents_Pipes_DynamicPipesAndFittings" error: [initialize] Initialization of system "model.root" failed error: [SimulateSingleFMU] oms_initialize failed info: 2 warnings info: 5 errors