/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_IDEAS_IDEAS_Examples_Tutorial_Example8_fmu --startTime=1e+07 --stopTime=1.1e+07 --timeout=50 --tolerance=1e-06 IDEAS_IDEAS_Examples_Tutorial_Example8.fmu LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 10000000.000000 | | | | ((pumpSec.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 10000000.000000 | | | | ((pumpPrim.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." info: maximum step size for 'model.root': 2000.000000 info: Result file: model_res.mat (bufferSize=10) info: Parameter model.root.IDEAS_IDEAS_Examples_Tutorial_Example8.jsonWri.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Examples_Tutorial_Example8.jsonWri.varKeys[1] will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/HeatPumps/Compressors/BaseClasses/PartialCompressor.mo:85:3-87:42:writable] | | | | The following assertion has been violated at time 10060000.000000 | | | | ((heaPum.com.port_b.T > 173.15 and heaPum.com.port_b.T < 345.25)) --> "Condensing temperature must be above the minimum refrigerant temperature | | | | and below the critical temperature." error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_IDEAS.Examples.Tutorial.Example8/temp_IDEAS_IDEAS_Examples_Tutorial_Example8_fmu/model-xm1khev1/temp/0001_IDEAS_IDEAS_Examples_Tutorial_Example8 (logFmi2Call): fmi2CompletedIntegratorStep: terminated by an assertion. error: [doStep] fmi2_completedIntegratorStep failed for FMU "model.root.IDEAS_IDEAS_Examples_Tutorial_Example8" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/HeatPumps/Compressors/BaseClasses/PartialCompressor.mo:85:3-87:42:writable] | | | | The following assertion has been violated at time 10060000.000000 | | | | ((heaPum.com.port_b.T > 173.15 and heaPum.com.port_b.T < 345.25)) --> "Condensing temperature must be above the minimum refrigerant temperature | | | | and below the critical temperature." error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_IDEAS.Examples.Tutorial.Example8/temp_IDEAS_IDEAS_Examples_Tutorial_Example8_fmu/model-xm1khev1/temp/0001_IDEAS_IDEAS_Examples_Tutorial_Example8 (logFmi2Call): fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable rectangularZoneTemplate1.winC.propsBus_a.use_custom_q50 info: Final Statistics for 'model.root': NumSteps = 148 NumRhsEvals = 227 NumLinSolvSetups = 48 NumNonlinSolvIters = 226 NumNonlinSolvConvFails = 0 NumErrTestFails = 18 info: 0 warnings info: 4 errors